Extension Fan 1-3 Middle. Duty Cycle

Page 57 highlights

The following items appear only when you set the Extension Fan Profile to [Manual]. Extension Fan 1-3 Upper Temperature Use the or keys to adjust the upper limit of the extension fan temperature. The extension fan will operate at the maximum duty cycle when the temperature source is higher than the limit. Extension Fan 1-3 Max. Duty Cycle (%) Use the or keys to adjust the maximum extension fan duty cycle. When the temperature source reaches the upper limit, the extension fan will operate at the maximum duty cycle. Extension Fan 1-3 Middle Temperature Use the or keys to adjust the middle limit of the extension fan temperature. Extension Fan 1-3 Middle. Duty Cycle (%) Use the or keys to adjust the extension fan middle duty cycle. Extension Fan 1-3 Lower Temperature Use the or keys to adjust the lower limit of the extension fan temperature. The extension fan will operate at the minimum duty cycle when the temperature source is lower than the limit. Extension Fan 1-3 Min. Duty Cycle(%) Use the or keys to adjust the minimum extension fan duty cycle. When the temperature source is under the limit, the extension fan will operate at the minimum duty cycle. Allow Fan Stop This item allows your fans to run at 0% duty cycle when the temperature of the source drops below the lower temperature. Configuration options: [Disabled] [Enabled] W_PUMP+ Control [Disabled] Disable the Water Pump control feature. [Auto] Detects the type of water pump installed and automatically switches the control modes. [DC mode] Enable the Water Pump control in DC mode for 3-pin chassis fan. [PWM mode] Enable the Water Pump control in PWM mode for 4-pin chassis fan. The following items appear only when you set the Water Pump Control to [Auto], [DC mode] or [PWM mode]. Water Pump Upper Temperature Use the or keys to adjust the upper limit of the water pump temperature. Water Pump Max. Duty Cycle (%) Use the or keys to adjust the maximum water pump duty cycle. When the CPU temperature reaches the upper limit, the Water Pump will operate at the maximum duty cycle. ASUS TUF Z270 MARK 1 BIOS Manual 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

ASUS TUF Z270 MARK 1 BIOS Manual
57
The following items appear only when you set the Extension Fan Profile to
[Manual]
.
Extension Fan 1-3 Upper Temperature
Use the <+> or <-> keys to adjust the upper limit of the extension fan
temperature. The extension fan will operate at the maximum duty cycle
when the temperature source is higher than the limit.
Extension Fan 1-3 Max. Duty Cycle (%)
Use the <+> or <-> keys to adjust the maximum extension fan duty cycle.
When the temperature source reaches the upper limit, the extension fan
will operate at the maximum duty cycle.
Extension Fan 1-3 Middle Temperature
Use the <+> or <-> keys to adjust the middle limit of the extension fan
temperature.
Extension Fan 1-3 Middle. Duty Cycle (%)
Use the <+> or <-> keys to adjust the extension fan middle duty cycle.
Extension Fan 1-3 Lower Temperature
Use the <+> or <-> keys to adjust the lower limit of the extension fan
temperature. The extension fan will operate at the minimum duty cycle
when the temperature source is lower than the limit.
Extension Fan 1-3 Min. Duty Cycle(%)
Use the <+> or <-> keys to adjust the minimum extension fan duty cycle.
When the temperature source is under the limit, the extension fan will
operate at the minimum duty cycle.
Allow Fan Stop
This item allows your fans to run at 0% duty cycle when the temperature of
the source drops below the lower temperature.
Configuration options: [Disabled] [Enabled]
W_PUMP+ Control
[Disabled]
Disable the Water Pump control feature.
[Auto]
Detects the type of water pump installed and automatically
switches the control modes.
[DC mode]
Enable the Water Pump control in DC mode for 3-pin chassis fan.
[PWM mode]
Enable the Water Pump control in PWM mode for 4-pin chassis
fan.
The following items appear only when you set the Water Pump Control to
[Auto]
,
[DC
mode]
or
[PWM mode].
Water Pump Upper Temperature
Use the <+> or <-> keys to adjust the upper limit of the water pump
temperature.
Water Pump Max. Duty Cycle (%)
Use the <+> or <-> keys to adjust the maximum water pump duty cycle.
When the CPU temperature reaches the upper limit, the Water Pump will
operate at the maximum duty cycle.