Page 54 highlights
Using the Q-Code logger Q-Code Logger allows you to easily check Q-Code event logs without opening the system's case. To use the Q-Code logger: 1. Insert the USB storage device to the dedicated Q-Code logger USB port. 2. Press the Q-Code logger button for three seconds until the Q-Code logger LED blinks three times, indicating that the Q-Code logger function is enabled. Q-Code logger port Q-Code logger button Using the USB Flashback USB BIOS Flashback allows you to easily update the BIOS without entering BIOS or operating system. To use USB Flashback: 1. Download the latest BIOS file from the ASUS website. 2. Extract and rename the BIOS image file to Z1016WS.CAP. 3. Copy Z1016WS.CAP to the root directory of your USB storage device. 4. Turn off the system and connect the USB storage device to the USB BIOS Flashback port. 5. Press the USB BIOS Flashback button. A flashing light indicates that the BIOS Flashback function is enabled. The light goes out when the process of updating the BIOS is complete. USB BIOS Flashback port 2-34 USB BIOS Flashback button Chapter 2: Hardware information