11 ULTRAGRAPH DIGITAL DEQ1024 System specifications Frequency response Signal-to-noise ratio THD Crosstalk Bypass Type Digital inputs Type Standard Input impedance Nom. input level Digital Outputs Type Standard Impedance Output level Digital processing Converter Sample rate Graphic equalizer Type Frequency range Bandwidth Control range Feedback Destroyer (FBD) Type Filter Frequency range Bandwidth Control range 15 Hz to 35 kHz, +/- 3 dB 104 dBu, a-weighted, 22 Hz - 22 kHz 0.004 % typ. @ +4 dBu, 1 kHz, gain 1 < -85 dB, 22 Hz - 22 kHz Master Gain Filter Low Cut High Cut -9 dB to +9 dB 20 Hz to 160 Hz (12 dB/oct.) 2.5 kHz to 16 kHz (12 dB/oct.) Relay, hard-bypass in case of power failure Dynamics Type gate and limiter with digital IGC (Interactive Gain Control) XLR transformer-balanced Threshold variable: -60 to -10 dB (gate) variable: -6 to +9 dB (limiter) AES/EBU or S/PDIF 110 Ω 0.2 - 5 V peak-to-peak Function switches Bypass Meter in/out switch, to deactivate equalizer functions selects between input and output metering XLR transformer-balanced Fader range sets the maximal cut/boost for the 31 bands AES/EBU or S/PDIF Standby switches into standby mode 110 Ω Pink noise -48 dB to 0 dB 2 - 5 V peak-to-peak FB indicator recognition of frequency band intensity 24-bit Delta-Sigma, 64/128 oversampling 44.1 kHz, 48 kHz, 96 kHz True Curve Displays Input/output level Algorithm for achieving filter curve linearity 12-digit LED display: -48/-36/-24/-18/ -12/-6/-3/0/+3/+6/+9 dB/CLIP analog 1/3-oct EQ 20 Hz to 20 kHz 31 1/3-oct. bands according to ISO frequencies 1/3-oct. +/-6, +/-12 dB or 0/-24 dB (switchable) Function switch Power supply Voltage Power consumption LED display of each switch (except for clock and configuration switches) 85 to 250 V~, 50/60 Hz, auto range typ. 10 W Fuse T 1A H digital signal analysis for feedback identification max. 10 digital notch filters per channel, automatic feedback suppression system 20 Hz - 20 kHz 1/10-oct. Mains connector Dimensions/Weight Dimensions (H x W x D) Shipping weight Standard IEC receptacle approx. 3.5 x 19 x 5.3" approx. 89 x 482.6 x 135 mm approx. 2.5 kg / 5 lbs -48 dB in 6 dB-steps BEHRINGER continuously strives to assure the highest quality standards possible. Required modifications may be implemented without prior notice. Technical data and the appearance of the unit may deviate from the above values and/or illustrations.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

11
ULTRAGRAPH DIGITAL DEQ1024
System specifications
Frequency response
15 Hz to 35 kHz, +/- 3 dB
Signal-to-noise ratio
104 dBu, a-weighted, 22 Hz - 22 kHz
THD
0.004 % typ. @ +4 dBu, 1 kHz, gain 1
Crosstalk
< -85 dB, 22 Hz - 22 kHz
Bypass
Type
Relay, hard-bypass in case of
power failure
Digital inputs
Type
XLR transformer-balanced
Standard
AES/EBU or S/PDIF
Input impedance
110 Ω
Nom. input level
0.2 - 5 V peak-to-peak
Digital Outputs
Type
XLR transformer-balanced
Standard
AES/EBU or S/PDIF
Impedance
110 Ω
Output level
2 - 5 V peak-to-peak
Digital processing
Converter
24-bit Delta-Sigma,
64/128 oversampling
Sample rate
44.1 kHz, 48 kHz, 96 kHz
Graphic equalizer
Type
analog 1/3-oct EQ
Frequency range
20 Hz to 20 kHz 31 1/3-oct. bands
according to ISO frequencies
Bandwidth
1/3-oct.
Control range
+/-6, +/-12 dB or 0/-24 dB (switchable)
Feedback Destroyer (FBD)
Type
digital signal analysis for
feedback identification
Filter
max. 10 digital notch filters per channel,
automatic feedback suppression system
Frequency range
20 Hz - 20 kHz
Bandwidth
1/10-oct.
Control range
-48 dB in 6 dB-steps
Master
Gain
-9 dB to +9 dB
Filter
Low Cut
20 Hz to 160 Hz (12 dB/oct.)
High Cut
2.5 kHz to 16 kHz (12 dB/oct.)
Dynamics
Type
gate and limiter with digital IGC
(Interactive Gain Control)
Threshold
variable: -60 to -10 dB (gate)
variable: -6 to +9 dB (limiter)
Function switches
Bypass
switch, to deactivate equalizer functions
Meter in/out
selects between input and
output metering
Fader range
sets the maximal cut/boost
for the 31 bands
Standby
switches into standby mode
Pink noise
-48 dB to 0 dB
FB indicator
recognition of frequency
band intensity
True Curve
Algorithm for achieving filter
curve linearity
Displays
Input/output level
12-digit LED display: -48/-36/-24/-18/
-12/-6/-3/0/+3/+6/+9 dB/CLIP
Function switch
LED display of each switch (except for
clock and configuration switches)
Power supply
Voltage
85 to 250 V~, 50/60 Hz, auto range
Power consumption
typ. 10 W
Fuse
T
1 A
H
Mains connector
Standard IEC receptacle
Dimensions/Weight
Dimensions (H x W x D)
approx. 3.5 x 19 x 5.3
"
approx. 89 x 482.6 x 135 mm
Shipping weight
approx. 2.5 kg / 5 lbs
BEHRINGER
continuously strives to assure the highest quality standards possible. Required modifications may
be implemented without prior notice. Technical data and the appearance of the unit may deviate from the above
values and/or illustrations.