Behringer RD-9 Manual - Page 21

Parameters

Page 21 highlights

21 RHYTHM DESIGNER RD-9 User Manual 13. Parameters There are three different types of data files used by the RD-9. The contents of these file types are described herein. Global Settings File All of the RD-9's Settings and Preferences are stored in the Global Settings file. This file is loaded from Storage Memory when the unit is powered on. The exact contents of the file are described below: Settings Settings in the Global Settings file are automatically saved back to Storage Memory whenever they are changed. Setting Name Description Values Data Version Product Variant Last Loaded Song Last Loaded Pattern Device ID Clock Source Analog Clock Mode MIDI RX Channel MIDI TX Channel MIDI to USB Thru MIDI Soft Thru USB TX Channel USB to MIDI Thru Voice Note Mappings (1 - 11) Song Chain Mode Enhanced Mode From time to time, new versions of the RD-9 firmware will be released. This firmware will contain both bug fixes and new features. Additional parameters may be added to the Global Settings Data file to support those new features. The Global Settings Data file is therefore versioned to guarantee compatibility between firmware releases. The RD-9 is one of a number of Behringer products that sequence songs. This parameter is used to distinguish between RD-9 Song Data files and other song data files. Each time a song is loaded into the sequencer it is logged. When you power on the unit, the last song to be logged before the unit was powered off will be loaded back into the sequencer. Each time a pattern is loaded in the sequencer it is logged. When you power on the unit, the last pattern to be logged before the unit was powered of will be loaded back into the sequencer. Each RD unit in a system can have its own unique ID number. Press Sync to cycle through the 4 clock source options. Choose the type of clock that the clock input follows. Set the MIDI in receive channel. Set the MIDI out transmit channel. Set MIDI in to send to USB Thru. Send all MIDI in Data to the MIDI out port. Set the USB MIDI receive channel. Set the USB MIDI transmit channel. Send the USB MIDI in to the MIDI thru port. Voice MIDI note map. Can be changes from the default if desired. Chain songs together for live performance. Trigger Out Assign Set the enhanced mode. Set the trigger out to follow which voice 1 - 16 1 - 16 1 - 16 INT, MIDI, USB or CLK 1, 2, 4, 24 and 48PP 1 - 16 1 - 16 On/Off On/Off 1 - 16 1 - 16 On/Off various 0 - Hold, 1 - Loop, 2 - Stop On/Off 0 - Bass Drum, 1 - Snare Drum, 2 - LOW TOM, 3 - MID TOM, 4 - HI TOM, 5 - RIM SHOT, 6 - CLAP

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

21
RHYTHM DESIGNER RD-9 User Manual
13.
Parameters
There are three different types of data files used by the RD-9. The contents of these file types are described herein.
Global Settings File
All of the RD-9’s Settings and Preferences are stored in the Global Settings file. This file is loaded from Storage Memory when the unit is powered on. The exact
contents of the file are described below:
Settings
Settings in the Global Settings file are automatically saved back to Storage Memory whenever they are changed.
Setting Name
Description
Values
Data Version
From time to time, new versions of the RD-9 firmware will be released. This firmware will
contain both bug fixes and new features. Additional parameters may be added to the Global
Settings Data file to support those new features. The Global Settings Data file is therefore
versioned to guarantee compatibility between firmware releases.
Product Variant
The RD-9 is one of a number of Behringer products that sequence songs. This parameter is used
to distinguish between RD-9 Song Data files and other song data files.
Last Loaded Song
Each time a song is loaded into the sequencer it is logged. When you power on the unit, the
last song to be logged before the unit was powered off will be loaded back into the sequencer.
1 – 16
Last Loaded Pattern
Each time a pattern is loaded in the sequencer it is logged. When you power on the unit,
the last pattern to be logged before the unit was powered of will be loaded back into the
sequencer.
1 – 16
Device ID
Each RD unit in a system can have its own unique ID number.
1 – 16
Clock Source
Press Sync to cycle through the 4 clock source options.
INT, MIDI, USB or CLK
Analog Clock Mode
Choose the type of clock that the clock input follows.
1, 2, 4, 24 and 48PP
MIDI RX Channel
Set the MIDI in receive channel.
1 – 16
MIDI TX Channel
Set the MIDI out transmit channel.
1 – 16
MIDI to USB Thru
Set MIDI in to send to USB Thru.
On/Off
MIDI Soft Thru
Send all MIDI in Data to the MIDI out port.
On/Off
USB TX Channel
Set the USB MIDI receive channel.
1 – 16
USB to MIDI Thru
Set the USB MIDI transmit channel.
1 – 16
Voice Note Mappings
(1 - 11)
Send the USB MIDI in to the MIDI thru port.
On/Off
Song Chain Mode
Voice MIDI note map. Can be changes from the default if desired.
various
Enhanced Mode
Chain songs together for live performance.
0 – Hold,
1 – Loop,
2 – Stop
Trigger Out Assign
Set the enhanced mode.
On/Off
Set the trigger out to follow which voice
0 – Bass Drum,
1 – Snare Drum,
2 – LOW TOM,
3 – MID TOM,
4 – HI TOM,
5 – RIM SHOT,
6 – CLAP