Biostar TF560 A2 Setup Manual - Page 25

Raid 5 - driver download

Page 25 highlights

TF520 A2+/TF560 A2+ RAID 5: RAID 5 stripes both data and parity information across three or more drives. It writes data and parity blocks across all the drives in the array. Fault tolerance is maintained by ensuring that the parity information for any given block of data is placed on a different drive from those used to store the data itself. Features and Benefits ­ Drives: Minimum 3. ­ Uses: RAID 5 is recommended for transaction processing and general purpose service. ­ Benefits: An ideal combination of good performance, good fault tolerance, and high capacity and storage efficiency. ­ Drawbacks: Individual block data transfer rate same as a single disk. Write performance can be CPU intensive. ­ Fault Tolerance: Yes. Disk 1 DATA 1 DATA 3 PARITY DATA 7 DATA 9 PARITY Disk 2 DATA 2 PARITY DATA 5 DATA 8 PARITY DATA 11 Disk 3 PARITY DATA 4 DATA 6 PARITY DATA 10 DATA 12 ※ For more detailed setup information, please refer to the Driver CD, or go to http://www.nvidia.com/page/pg_20011106217193.html to download NVIDIA nForce Tutorial Flash. 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

TF520 A2+/TF560 A2+
23
RAID 5:
RAID 5 stripes both data and parity information across three or more drives. It writes
data and parity blocks across all the drives in the array. Fault tolerance is maintained by
ensuring that the parity information for any given block of data is placed on a different
drive from those used to store the data itself.
Features and Benefits
±
Drives:
Minimum 3.
±
Uses:
RAID 5 is recommended for transaction processing and general
purpose service.
±
Benefits:
An ideal combination of good performance, good fault tolerance,
and high capacity and storage efficiency.
±
Drawbacks:
Individual block data transfer rate same as a single disk. Write
performance can be CPU intensive.
±
Fault Tolerance:
Yes.
Disk 1
DATA 3
PARITY
DATA 7
DATA 1
DATA 9
PARITY
Disk 2
PARITY
DATA 5
DATA 8
DATA 2
PARITY
DATA 11
Disk 3
DATA 4
DATA 6
PARITY
PARITY
DATA 10
DATA 12
For more detailed setup information, please refer to the Driver CD, or go to
to download NVIDIA nForce Tutorial Flash.