Page 16 highlights
IMPORTANT INFORMATION Connect the regulator Figure 3 (2) to the manifold The voltage and total power must be checked on Figure 3 (1) as shown by the arrow on the regulator, the specifications plate. This appliance must be applying teflon to the threads. grounded. Connect the pressure regulator to the gas grid using a flexible gas line fitting between the shutoff valve and the pressure regulator. Figure 3. Figure 3 1 Always ensure that all connections have been made in accordance with code requirements. Thoroughly follow the requisites of the local electric power company. The electrical connection (CA 110-127 V) is established by a connection cable with a grounding contact plug connected to a grounded outlet to which there must be access after installation of the gas cooktop. All gas connections must be tested for leaks using an appropriate liquid solution. Never use a flame to test for gas leaks. 2 Ensure that a bag containing component 2 is supplied with the appliance. If this component is missing, call our Technical Service. Use the parts we supply to complete the gas connection. Tighten the appliance regulador to 15 to 22 ft-lbs of torque. Never tighten to more than 26 ft-lbs of tor- que. Always use an approved pipe joint compound resistant to the action of LP gas. Connection using a metal pipe. In this case, contact between this tube and the moving parts of the kitchen unit (for example, a drawer) and its passage through areas that could be blocked, must be avoided. The manufacturer accepts no responsibility for leaks or connections carried out by the installation technician. Leak testing according to omf athneufaapcptuliraenrc,seisnhsatrlul cbteiocnosn.ducted Electrical connection Before connecting the power cable to the wall outlet, make sure the gas shut-off valve and all the control knobs of the burners are set to "off". WARNING: this appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle. Do not cut or remove the grounding prong from this plug. The current supply connection cable must be at least of the JT 3x18 AWG/UL/CSA variety, or should be heat-resistant (at least 105 ºC / 221 ºF). The mains connecting cable must only be purchased through and connected by an authorised specialist. Do not tamper with the inside of the appliance. If this is necessary, call our technical assistance service. 16