Bosch PGL985UC Operating Instructions - Page 17

From natural gas to propane, Gas type changing - ratings

Page 17 highlights

IMPORTANT INFORMATION Gas type changing: From natural gas to propane It is necessary that all operations related with installation, adjustment or adaptation LP gas be performed by authorized personnel of our Technical Service, and that the regulations in force, as well as the requisites of the gas companies, be followed. IMPORTANT: Before you begin, turn off the gas and electricity supply to the appliance. Before connecting up the appliance to the installation, first check that it has been adjusted for the type of gas that is to be supplied. Our cooktops are delivered from factory prepared to operate with the gas type indicated on the specifications plate. The propane gas tank must be equipped with its own high pressure regulator in addition to the pressure regulator supplied with this unit. Supply Pressure Natural Gas - 7" wc (17.5 mbar) minimum. Propane Gas - 11" wc (27.4 mbar) minimum. The maximum supply pressure to this appliance shall not exceed 14" water column (34.9 mbar). This cooktop can be adapted to work with LP gas. To do so, the following procedures must be completed: A) Change of cooktop burner tips. (See table1). T ABLE 1 Burner data The burner must be used with the G A S gases indicated on the TYPE specifications plate. NATURAL PROPANE Gas pressure for use Burner Burner tip marker Rapid Consumption Rated (Hs) BTU/hr 6" 133 10.000 10" 95 10.000 Burner semirapid Burner tip marker Consumption Rated (Hs) BTU/hr 110 7.000 77 7.000 Burner Auxiliary Burner tip marker Consumption Rated (Hs) BTU/hr 98 5.500 69 5.500 Large Burner tip marker Burner Consumption Rated Triple-flame (Hs) BTU/hr 106/81 15.300 72/55 15.300 Figure 4 Figure 5 1 - Remove the grates, covers and the main body of the burner. 2 - Change the burner tips using a 7 mm socket wrench and make sure that they are tightened all the way in order to ensure that they are correctly sealed. Figure 4. The adjustment of primary air must not be performed on these burners. B) Reduced consumption adjustment of the cooktop burner taps. 1 - Set the taps to the minimum setting. 2 - Remove the control knobs from the taps. Figure 5. 3 - Remove the anti-spillage disc seals. 7 mm. 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57

17
IMPORTANT INFORMATION
body of the burner.
2 -
Change the burner tips using a 7 mm socket
wrench and make sure that they are tightened all
the way in order to ensure that they are correctly
sealed. Figure 4.
The adjustment of primary air must not be performed
on these burners.
1 -
Set the taps to the minimum setting.
2 -
Remove the control knobs from the taps.
Figure 5.
3 -
Remove the anti-spillage disc seals.
From natural gas to propane
It is necessary that all operations related with
of our Technical Service, and that the regulations
in force, as well as the requisites of the gas
companies, be followed.
IMPORTANT:
Before you begin, turn off the gas
and electricity supply to the appliance.
Before connecting up the appliance to the
installation, first check that it has been adjusted
for the type of gas that is to be supplied. Our
to operate with the gas type indicated on the
specifications plate.
A)
Figure 5
T ABLE 1
Burner data
The burner must be used with the
gases indicated on the
specifications plate.
GAS
TYPE
NATURAL
PROPANE
Gas pressure for use
6”
10”
Burner tip marker
Burner tip marker
Burner tip marker
Burner tip marker
Burner
Rapid
Burner
semi-
rapid
Burner
Auxiliary
Large
Burner
Triple-flame
Consumption
(Hs)
Rated
Consumption
(Hs)
Rated
Consumption
(Hs)
Rated
Consumption
(Hs)
Rated
133
95
BTU/hr
BTU/hr
BTU/hr
BTU/hr
10.000
10.000
7.000
7.000
98
106/81
72/55
5.500
5.500
15.300
15.300
110
77
Gas type changing:
1 -
Remove the grates, covers and the main
installation,
adjustment
or
adaptation
LP
gas
be
performed
by
authorized
personnel
The propane gas tank must be equipped with its
own high pressure regulator in addition to the
pressure regulator supplied with this unit.
The
maximum
supply
pressure
to
this
appliance
procedures
must
be
completed:
with
LP
gas.
To
do
so,
the
following
shall
not
exceed
14"
water
column
(34.9
mbar).
cooktops are delivered from factory prepared
This
cooktop
can
be
adapted
to
work
Change
of
cooktop
burner
tips.
(See
table1).
B)
Reduced consumption adjustment of the cooktop
burner taps.
69
Supply Pressure
Natural
Gas
-
7"
wc
(17.5
mbar)
minimum.
Propane Gas - 11" wc (27.4 mbar) minimum.
7 mm.
Figure 4