Electrical connection d CAUTION d Power cord must be connected by a qualified person only. Connect to individual Brunch Circuit. Do not use an adapter. Do not use an extension cord. Do not remove ground prong. For CANADA Your dryer comes with a power supply cord, CSA listed in Canada. The Bosch dryer requires a 4Ćwire receptacle. When installing the receptacle for the dryer cord, ensure that the power supply cord is accessible when the dryer is in the installed position. The power cord should only be replaced by a qualified person. Use a 4Ćwire power supply cord (see electrical connection U.S.A. below). For U.S.A. Your dryer comes without a power supply cord. The power cord must meet the following requirements: - UL listed in the USA - 208 ć 240 volt rated (minimum) - 30 amps - Type SRDT or DRT (UL 2158) - Five feet long (minimum) - suitable for dryer 8 d CAUTION d Power cord must be connected by a licensed electrician only. Use only a U.L. approved 30 amp power cord with strain relief clamp note manufacturer's instructions. Do not plug end of power cord into a live receptacle before conĆ necting power cord to appliance terminals and closing junction/ splitter box as described below. Do not reuse old power cord. Cord must have closed loop or upturned end wire terminating connectors. Do not make a sharp bend or crimp wiring/conductor at conĆ nections. Only a 4Ćconductor cord shall be used when the appliance is installed in a mobile home, in a recreational vehicle, in a new branch circuit installation or an area where the local codes do not permit grounding through the neutral. The splitting box is located at the top rear of the appliance. To connect the power cord you have to remove the cover plate. 1. Remove the screws of the cover plate on the rear side of the appliance. 2. Push the cover plate from the front to the rear side and lift up. 3. Open the splitting box in the right corner (20 Torx). 4. Loosen the strain relief in the appliance. 5. Thread the power cord through the U.L. strain relief clamp. 6. Tighten the screws (2.5 Nm) of the U.L. strain relief clamp so that the power cord cannot be moved. 7. Connect the power cord as described below. 8. After connecting the power cord close the splitting box and replace the cover plate fasten in place with reverse handling. Dryer supplied to customer Connecting 4Ćwire power supply cord 1. Remove the screws from the cover of the terminal block. 2. Remove the screws from the grounding cable. 3. Remove the grounding cable. 4. Loosen the 2 screws labeled L in the terminal block. 5. Attach the power cord ground conductor (green) to the GROUND point. Tighten the screw (2.5 Nm) so that the ground conductor is held securely in place. 6. Attach the 2 power cord outer conductors (red and black) to the 2 terminals labeled L and the remaining power cord conductor (white) to the terminal labeled N.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

8
Electrical
connection
d
CAUTION
d
Power cord must
be
connected
by a
qualified person
only.
Connect
to
individual Brunch
Circuit.
Do not
use
an
adapter.
Do not
use
an
extension
cord.
Do not
remove
ground
prong.
For
CANADA
Your dryer comes
with
a
power
supply cord,
CSA
listed
in
Canada.
The
Bosch
dryer requires
a
4Ćwire
receptacle.
When installing
the
receptacle
for
the
dryer cord,
ensure that
the
power
supply cord is
accessible
when the
dryer is
in
the
installed
position.
The
power cord should
only be
replaced
by a
qualified
person.
Use±a
4Ćwire
power supply cord
(see
electrical connection
U.S.A.
below).
For
U.S.A.
Your dryer comes
without
a
power
supply cord.
The
power
cord
must
meet the
following
requirements:
-
UL listed in
the
USA
-
208
ć
240
volt
rated
(minimum)
-
30 amps
-
Type
SRDT
or DRT
(UL
2158)
-
Five
feet
long
(minimum)
-
suitable
for dryer
d
CAUTION
d
Power cord
must be connected
by a
licensed
electrician
only.
Use
only
a U.L. approved
30±amp
power
cord
with strain
relief
clamp
-
note
manufacturer's instructions.
Do
not plug
end
of
power
cord
into
a
live receptacle before conĆ
necting
power
cord
to
appliance
terminals and
closing
junction/
splitter box as
described
below.
Do
not reuse old
power
cord.
Cord
must have closed
loop
or
upturned
end
wire terminating
connectors.
Do
not make a sharp
bend
or
crimp
wiring/conductor
at conĆ
nections.
Only a 4Ćconductor
cord
shall
be±used
when the appliance is
installed
in a mobile home, in a
recreational vehicle, in a new
branch circuit installation or
an
area
where the local codes do
not
permit grounding
through
the
neutral.
The
splitting
box
is located
at the
top
rear
of
the appliance.
To
connect the power
cord
you
have
to
remove the cover
plate.
1.
Remove the screws
of
the
cover
plate on the rear
side of
the
appliance.
2.
Push the cover
plate
from the
front to
the rear
side
and lift
up.
3.
Open the splitting
box in
the
right corner
(20
Torx).
4.
Loosen the strain
relief
in
the
appliance.
5.
Thread
the power cord through
the U.L. strain relief
clamp.
6.
Tighten the screws (2.5±Nm) of
the U.L. strain relief
clamp so
that the power
cord cannot
be
moved.
7.
Connect the power cord as
described
below.
8.
After
connecting
the
power
cord
close the splitting box and
replace the cover
plate
fasten
in
place with reverse
handling.
Dryer supplied to customer
Connecting
4Ćwire
power supply
cord
1.
Remove the screws from the
cover
of
the terminal
block.
2.
Remove the screws from the
grounding
cable.
3.
Remove the grounding cable.
4.
Loosen the 2
screws labeled
L
in the terminal block.
5.
Attach the power
cord ground
conductor
(green) to the
GROUND point. Tighten
the
screw
(2.5
Nm) so that
the
ground
conductor is held
securely
in place.
6.
Attach the 2
power cord outer
conductors
(red
and black) to
the 2
terminals
labeled
L
and
the remaining
power cord
conductor
(white) to the
terminal labeled