Brother International DS-740D Quick Setup Guide - Page 7

DSmobile DS-940DW

Page 7 highlights

Product Safety Guide Important safety instructions DO NOT attempt to service the scanner yourself because disassembling the scanner may expose you to dangerous voltage points and other risks and may void your warranty. Refer all servicing to a Brother Authorized Service Center. For the location of your nearest Brother Authorized Service Center, contact: In USA: 1-877-BROTHER (1-877-276-8437) In Canada: www.brother.ca/support Rechargeable Li-ion battery (DSmobile DS-940DW only) • At the time of purchase, the rechargeable Li-ion battery is slightly charged so that the operation of the scanner can be verified; however, the rechargeable Li-ion battery should be fully charged via the USB port before the scanner is used. • If the scanner will not be used for a long period of time, store it in a location where it is not exposed to high humidity or high temperatures (temperatures between 59 °F/15 °C and 77 °F/25 °C and 40 to 60% humidity are recommended). In order to maintain the efficiency and life of the rechargeable Li-ion battery, charge it at least every three months. • If you notice anything unusual about the rechargeable Li-ion battery the first time it is used, for example overheating or rust, DO NOT continue to use the battery. Contact your Brother dealer or Brother customer service. Tips on using the rechargeable Li-ion battery (DSmobile DS-940DW only) • Charge the rechargeable Li-ion battery before use. Do not use the scanner until the rechargeable Liion battery has been fully charged. • The rechargeable Li-ion battery charging can take place in 41~102 °F (5~39 °C) environments. If the surrounding temperature is out of this range, the rechargeable Li-ion battery will not be charged, and the battery indicator will remain lit. • If the scanner is used when both the rechargeable Li-ion battery is installed and the scanner is connected to your computer, charging may stop even if the rechargeable Li-ion battery has not been fully charged. Rechargeable Li-ion battery characteristics (DSmobile DS-940DW only) Understanding the properties of the rechargeable Li-ion battery will allow you to optimize its usage. • Using or storing the rechargeable Li-ion battery in a location exposed to high or low temperatures may accelerate its deterioration. In particular, using a rechargeable Li-ion battery with a high charge (90% or more) in a location exposed to high temperatures will considerably accelerate battery deterioration. • Using the scanner while the rechargeable Li-ion battery is installed and charging may accelerate the battery's deterioration. • We recommend charging the scanner every three months to maintain the efficiency and life of the rechargeable Li-ion battery. • If you touch a part of the scanner while the rechargeable Li-ion battery is charging, that part of the scanner may feel warm. This is normal, and the scanner may be used safely. If the scanner becomes extremely hot, discontinue use. Surroundings temperature range Charge Standard discharge current 0.24 A Maximum discharge current 1.2 A Battery (Installed) Less than 1 month Less than 3 month Less than 1 year 32~113 °F (0~45 °C) 14~140 °F (-10~60 °C) 32~140 °F (0~60 °C) -4~113 °F (-20~45 °C) -4~95 °F (-20~35 °C) -4~77 °F (-20~25 °C) Charging parameters Maximum charging voltage Maximum charging current 4.35 Vdc 1200 mA 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

Product Safety Guide
7
DO NOT attempt to service the scanner yourself
because disassembling the scanner may expose you
to dangerous voltage points and other risks and may
void your warranty. Refer all servicing to a Brother
Authorized Service Center. For the location of your
nearest Brother Authorized Service Center, contact:
In USA: 1-877-BROTHER (1-877-276-8437)
In Canada: www.brother.ca/support
Rechargeable Li-ion
battery (DSmobile
DS-940DW only)
• At the time of purchase, the rechargeable Li-ion
battery is slightly charged so that the operation
of the scanner can be verified; however, the
rechargeable Li-ion battery should be fully charged
via the USB port before the scanner is used.
• If the scanner will not be used for a long period
of time, store it in a location where it is not
exposed to high humidity or high temperatures
(temperatures between 59 °F/15 °C and
77 °F/25 °C and 40 to 60% humidity are
recommended). In order to maintain the efficiency
and life of the rechargeable Li-ion battery, charge it
at least every three months.
• If you notice anything unusual about the
rechargeable Li-ion battery the first time it is used,
for example overheating or rust, DO NOT continue
to use the battery. Contact your Brother dealer or
Brother customer service.
• Charge the rechargeable Li-ion battery before use.
Do not use the scanner until the rechargeable Li-
ion battery has been fully charged.
• The rechargeable Li-ion battery charging can take
place in 41~102 °F (5~39 °C) environments. If the
surrounding temperature is out of this range, the
rechargeable Li-ion battery will not be charged,
and the battery indicator will remain lit.
• If the scanner is used when both the rechargeable
Li-ion battery is installed and the scanner is
connected to your computer, charging may stop
even if the rechargeable Li-ion battery has not
been fully charged.
Important safety
instructions
Tips on using the
rechargeable Li-ion battery
(DSmobile DS-940DW
only)
Rechargeable Li-ion
battery characteristics
(DSmobile DS-940DW
only)
Understanding the properties of the rechargeable
Li-ion battery will allow you to optimize its usage.
• Using or storing the rechargeable Li-ion battery
in a location exposed to high or low temperatures
may accelerate its deterioration. In particular,
using a rechargeable Li-ion battery with a high
charge (90% or more) in a location exposed to
high temperatures will considerably accelerate
battery deterioration.
• Using the scanner while the rechargeable Li-ion
battery is installed and charging may accelerate
the battery’s deterioration.
• We recommend charging the scanner every
three months to maintain the efficiency and life of
the rechargeable Li-ion battery.
• If you touch a part of the scanner while the
rechargeable Li-ion battery is charging, that part
of the scanner may feel warm. This is normal, and
the scanner may be used safely. If the scanner
becomes extremely hot, discontinue use.
Surroundings temperature range
Charge
32~113 °F
(0~45 °C)
Standard discharge current 0.24 A
14~140 °F
(-10~60 °C)
Maximum discharge current 1.2 A
32~140 °F
(0~60 °C)
Battery
(Installed)
Less than
1 month
-4~113 °F
(-20~45 °C)
Less than
3 month
-4~95 °F
(-20~35 °C)
Less than
1 year
-4~77 °F
(-20~25 °C)
Charging parameters
Maximum charging voltage
4.35 Vdc
Maximum charging current
1200 mA