Brother International Innov-is 80 Operation Manual - Page 129
Removing the needle plate
View all Brother International Innov-is 80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 129 highlights
Insert the bobbin case so that the S mark on h the bobbin case aligns with the z mark on machine as shown below. Insert the tabs on the needle plate cover into the i needle plate, and then slide the cover back on. • Align the S and z marks. a a Needle plate cover Install the flat bed attachment in its original j position. Removing the needle plate When the thread is tangled and cannot be removed by cleaning the race, remove the needle plate. Follow steps a through f on page 126. a Remove the needle plate by removing the b screws with the included screwdriver. 4 a Smark b zmark c Bobbin case • Make sure that the indicated points are aligned before installing the bobbin case. CAUTION ● Never use a bobbin case that is scratched, otherwise the upper thread may become tangled, the needle may break or sewing performance may suffer. For a new bobbin case (part code: XE7560-001), contact your nearest authorized service center. ● Be sure that the bobbin case is correctly installed, otherwise the needle may break. Remove the tangled thread from the needle c plate. Return the needle plate to its original position, and d then tighten the screws with the included screwdriver. Note z Align the two screw holes on the needle plate with the two holes on the machine. Follow steps g through j (page 126-127). e Care and Maintenance 127