ESC iXD2 Specify delimiter
View all Brother International TD-4420DN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
P-touch Template 2.0 Command Reference ESC iXD2 Specify delimiter ASCII: ESC i X D Decimal: 27 105 88 68 Hexadecimal: 1B 69 58 44 2 n1 n2 data 50 nd1 nd2 datad 32 nh1 nh2 datah Parameters 01h≤nh1≤14h nh2: 00h (Fixed) 00h≤datah≤FFh Description The delimiter is used to indicate when to move to the next object in data that is being sent. Specifies the text string for the delimiter. nh1+(nh2*256): Length of the text string (between 1 and 20) data: Text string (The maximum number of characters that can be set is 20 characters (bytes).) The default text string for the delimiter is "09h" (Tab code). This command is a static command. Remarks Invalid if more than 20 characters have been specified Example To change the delimiter to "," (2Ch): Since the text string contains one character, nh1=01h and nh2=00h. In addition, with the text string (datah) "," (2Ch), the command will be as follows. ESC i X D 2 01h 00h 2Ch (1Bh 69h 58h 44h 32h 01h 00h 2Ch) - 67 - 7. Control Command Details