CS616 and CS625 Water Content Reflectometers Timeout: The Timeout parameter is the maximum time duration, in milliseconds, that the datalogger will wait for the number of Cycles to be measured for the average calculation. An overrange value will be stored if the Timeout period is exceeded. A value of 1 is recommended if 10 is used for cycles parameter. Port: The Port parameter is the control port or analog channel that will be used to switch power to the CS625 Water Content Reflectometer. Valid options are: Code 0 C1 C2 3 4 5 P_SW Description None Control Port 1 Control Port 2 Analog Channel 3 Analog Channel 4 Analog Channel 5 Analog Channel 6/P_SW Mult, Offset: The Mult and Offset parameters are each a constant, variable, array, or expression by which to scale the results of the raw measurement. A multiplier value of 1 is recommended. 6.4.3 Sample Programs for CS625 TABLE 6-2. CS625 Sample Programs Sample Program Number 1 2 Program Description Measure volumetric water content with 4 CS625 hourly. Store average hourly readings to final storage every 4 hours. Measure temperature with 109 probe and use the 109 temperature to correct the period for 1 CS625. Use standard calibration equation to convert temperature-corrected period to volumetric water content. Sensors are read hourly and average water content and temperature are written to storage every 4 hours. 6.4.3.1 CS625 Sample Program 1 Hourly measure temperature with 109 probe and volumetric water content with 4 CS625. Store average hourly readings to final storage every 4 hours. CS625 leads CR200(X) greens Single-Ended Channel 1 thru 4 (SE1-4) blacks associated grounds for SE1-4 oranges Control Port 1 (C1) reds SW Battery clears G 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

CS616 and CS625 Water Content Reflectometers
Timeout
:
The
Timeout
parameter is the maximum time duration, in
milliseconds, that the datalogger will wait for the number of
Cycles
to be
measured for the average calculation. An overrange value will be stored if the
Timeout period is exceeded.
A value of 1 is recommended if 10 is used for
cycles parameter.
Port
:
The
Port
parameter is the control port or analog channel that will be used
to switch power to the CS625 Water Content Reflectometer. Valid options are:
Code
Description
0
None
C1
Control Port 1
C2
Control Port 2
3
Analog Channel 3
4
Analog Channel 4
5
Analog Channel 5
P_SW
Analog Channel 6/P_SW
Mult, Offset
:
The Mult and Offset parameters are each a constant, variable,
array, or expression by which to scale the results of the raw measurement.
A
multiplier value of 1 is recommended.
6.4.3 Sample Programs for CS625
TABLE 6-2.
CS625 Sample Programs
Sample
Program
Number
Program Description
1
Measure volumetric water content with 4 CS625 hourly.
Store
average hourly readings to final storage every 4 hours.
2
Measure temperature with 109 probe and use the 109
temperature to correct the period for 1 CS625.
Use standard
calibration equation to convert temperature-corrected period to
volumetric water content.
Sensors are read hourly and average
water content and temperature are written to storage every 4
hours.
6.4.3.1 CS625 Sample Program 1
Hourly measure temperature with 109 probe and volumetric water content with
4 CS625.
Store average hourly readings to final storage every 4 hours.
CS625 leads
CR200(X)
greens
Single-Ended Channel 1 thru 4 (SE1-4)
blacks
associated grounds for SE1-4
oranges
Control Port 1 (C1)
reds
SW Battery
clears
G