Canon LV-7215 lv7210_series_exp_cmd.pdf - Page 31

Cf_keydiscommand, 11.13 Cf_terminalcommand, 11.14 Cf_standbymodecommand, 11.15

Page 31 highlights

EXPAND SERIAL COMMAD FUNCTIONAL SPECIFICATION for LV-5210/7215/7210 Response value will return to the original setting. Acceptable "000" [CR] Unacceptable "Error Code" [CR] 8.11.12 CF_KEYDISCOMMAND COMMAND "CF_KEYDIS_%1" [CR] N/A" --- RC and KEY are available %1 "RC" ...Bar the use of RC "KEY" ...Bar the use of KEY Details Set bar the use of RC/KEY. (Only valid when it is in the usual Power ON status.) Response Acceptable "000" [CR] Unacceptable "Error Code" [CR] 8.11.13 CF_TERMINALCOMMAND COMMAND "CF_TERMINAL_%1" [CR] %1 "COMPUTER"...... Set Input mode "MONITOR".......... Set Monitor Out Mode Details Set TERMINAL(Only valid when it is in the usual Power ON status.) In this model, Terminal is COMPTUER2. Response Acceptable "000" [CR] Unacceptable "Error Code" [CR] 8.11.14 CF_STANDBYMODECOMMAND COMMAND "CF_STANDBYMODE_%1" [CR] %1 "ECO Standby power requirement is smaller "NORMAL".... Normal Standby power requirement Details Set STANDBYMODE (Only valid when it is in the usual Power ON status.) Response Acceptable "000" [CR] Unacceptable "Error Code" [CR] 8.11.15 CF_POINTERCOMMAND COMMAND "CF_POINTER_%1_%2" [CR] "SPOTLIGHT".......... Select Spotlight %1 "ARROW Select Arrow "FINGER Select Finger "LASER Select Laser mark "MAX Maximum Spotlight %2 "MID Medium Spotlight "MIN Minimum Spotlight Details Select POINTER image (Only valid when it is in the usual Power ON status.) Note1) %2 is available when "SPOTLIGHT" is specified only. When "ARROW"/"FINGER"/"LASER", specify "CF_POINTER_%1" [CR]. Note2) When "SPOTLIGHT", %2 cannot be omitted. Page 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

EXPAND SERIAL COMMAD FUNCTIONAL SPECIFICATION
for LV-5210/7215/7210
value will return to the original setting.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.11.12 CF_KEYDISCOMMAND
COMMAND
“CF_KEYDIS_%1” [CR]
%1
N/A”
--- RC and KEY are available
“RC”
...Bar the use of RC
“KEY”
...Bar the use of KEY
Details
Set bar the use of RC/KEY. (Only valid when it is in the usual Power ON
status.)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.11.13 CF_TERMINALCOMMAND
COMMAND
“CF_TERMINAL_%1” [CR]
%1
“COMPUTER”
......
Set Input mode
“MONITOR”
..........
Set Monitor Out Mode
Details
Set TERMINAL(Only valid when it is in the usual Power ON status.)
In this model, Terminal is COMPTUER2.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.11.14 CF_STANDBYMODECOMMAND
COMMAND
“CF_STANDBYMODE_%1” [CR]
%1
“ECO”
................
Standby power requirement is smaller
“NORMAL”
....
Normal Standby power requirement
Details
Set STANDBYMODE (Only valid when it is in the usual Power ON status.)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.11.15 CF_POINTERCOMMAND
COMMAND
“CF_POINTER_%1_%2” [CR]
%1
“SPOTLIGHT”..…….. Select Spotlight
“ARROW”
....................
Select Arrow
“FINGER”
..............
…. Select Finger
“LASER”
....................
Select Laser mark
%2
“MAX”
............................
Maximum Spotlight
“MID”
............................
Medium Spotlight
“MIN”
............................
Minimum Spotlight
Details
Select POINTER image (Only valid when it is in the usual Power ON
status.)
Note1)
%2
is
available
when
“SPOTLIGHT”
is
specified
only.
When ”ARROW”/”FINGER”/”LASER”, specify ”CF_POINTER_%1” [CR].
Note2) When “SPOTLIGHT”, %2 cannot be omitted.