Canon LV-7225 Basic_Serial_Command_Codes - Page 17

State Read Command, 1. Format, 2. Transfer Example, 3. Status Read Command, Details for Response}

Page 17 highlights

Basic Serial Command Functional Specification Page 16 of 19 7. State Read Command 7.1. Format 7.1.1. PC issues commands fin format as below. "CR" COMMAND [CR] Command: 1 character (See Status Read Command Table) 7.1.2. When a Projector receives the appropriate command, it returns a character line as the required data. Required Data [CR] Required Data: A character line (See Basic Status Read Command Table) 7.1.3. When receiving data cannot be decode, the Projector returns, "?" [CR]. 7.2. Transfer Example Get input mode for the Projector by basic commands. Command (current input mode command issue) PC → Projector "C" "R" "1" CR Projector → PC "1" CR Response (A few ms - 1s) (Shows Computer 1 is selected) 7.3. Status Read Command Command "CR0" [CR] Detail Get the Projector status Acceptable "%1" [CR] Response "00" = Power On "80" = Standby "40" = Processing Count down "20" = Processing Cooling down "10" = Abnormal Power %1 "28" = Processing cooling down due to abnormal temperature "08" = Abnormal Temperature "88" = Normal after recovering abnormal temperature "02" = Cannot accept RS232C command "24" = Processing Power Save・Cooling Down "04" = Power Save Unacceptable "?" [CR] {Details for Response} 7.3.1. "00" [CR] Status: Power On The image is displayed normally. 7.3.2. "80" [CR] Status: Standby When the status is Standby, Status Read Commands are always acceptable, but Functional Execution Commands are not acceptable except Power On Command.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Basic Serial Command Functional Specification
Page 16 of 19
7.
State Read Command
7.1. Format
7.1.1. PC issues commands fin format as below.
±CR² COMMAND [CR]
Command: 1 character (See Status Read Command Table)
7.1.2. When a Projector receives the appropriate command, it returns a character line as the required
data.
Required Data [CR]
Required Data: A character line (See Basic Status Read Command Table)
7.1.3. When receiving data cannot be decode, the Projector returns,
±?² [CR].
7.2. Transfer Example
Get input mode for the Projector by basic commands.
Command (current input mode command issue)
PC
Projector
±C²
±R²
±1²
CR
Projector
PC
±1²
CR
Response
(A few ms - 1s)
(Shows Computer 1 is selected)
7.3. Status Read Command
Command
±CR0² [CR]
Detail
Get the Projector status
Acceptable
±%1² [CR]
%1
±00² = Power On
±80² = Standby
±40² = Processing Count down
±20² = Processing Cooling down
±10² = Abnormal Power
±28² = Processing cooling down due to abnormal temperature
±08² = Abnormal Temperature
±88² = Normal after recovering abnormal temperature
±02² = Cannot accept RS232C command
±24² = Processing Power Save
Cooling Down
±04² = Power Save
Response
Unacceptable
±?² [CR]
{Details for Response}
7.3.1. ±00² [CR]
Status: Power On
The image is displayed normally.
7.3.2. ±80² [CR]
Status: Standby
When the status is Standby, Status Read Commands are always acceptable, but Functional
Execution Commands are not acceptable except Power On
Command.