Canon LV-7225 Basic_Serial_Command_Codes - Page 19

Input Mode Read Command, 5. Lamp Time Read Command, 6. Setting Read Command - no signal

Page 19 highlights

Basic Serial Command Functional Specification Page 18 of 19 7.3.10. "24" [CR] Status: Processing Cooling down by power save Cooling down by the Power Management function in the Setting menu. The control command is invalid. This Cooling down by Power save moves to Power save after the cooling down time. Status: No signal Response: "00" Cooling Down by Power Save "24" Power Save "04" After 5 minutes with no signal After about 90 seconds 7.3.11. "04" [CR] Status: Power Save The status is Power Save by the Power management function in setting menu. 7.4. Input Mode Read Command Command "CR1" [CR] Detail Get selected Input No. Acceptable "%1" [CR] Response "1" = Computer 1 %1 "2" = Computer 2 "3" = Video Unacceptable "?" [CR] 7.5. Lamp Time Read Command Command "CR3" [CR] Detail Get total lamp running hours. Acceptable "%1" [CR] Response %1 Show as 4 digits Ex.: "0410" [CR] ---- 410 hours Unacceptable "?" [CR] 7.6. Setting Read Command Command "CR4" [CR] Detail Get setting status for screen such as Ceiling / Rear. Acceptable "%1" [CR] Response "11" = Normal Screen Setting %1 "10" = Top and Bottom reversal setting (Rear&Ceiling On) "01" = Left and Right reversal setting (Rear On) "00" = Top / Bottom and Left / Right reversal setting (Ceiling On) Unacceptable "?" [CR]

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Basic Serial Command Functional Specification
Page 18 of 19
7.3.10. ±24² [CR]
Status: Processing Cooling down by power save
Cooling down by the Power Management function in the Setting menu.
The control command is invalid.
This Cooling down by Power save moves to Power save after the cooling down time.
Status:
No signal
Cooling Down by Power Save
Power Save
Response:
±00²
±24²
±04²
After 5 minutes with no signal
After about 90
seconds
7.3.11. ±04² [CR]
Status: Power Save
The status is Power Save by the Power management function in setting menu.
7.4. Input Mode Read Command
Command
±CR1² [CR]
Detail
Get selected Input No.
Acceptable
±%1² [CR]
%1
±1² = Computer 1
±2² = Computer 2
±3² = Video
Response
Unacceptable
±?² [CR]
7.5. Lamp Time Read Command
Command
±CR3² [CR]
Detail
Get total lamp running hours.
Acceptable
±%1² [CR]
%1
Show as 4 digits
Ex.: ±0410² [CR] ---- 410 hours
Response
Unacceptable
±?² [CR]
7.6. Setting Read Command
Command
±CR4² [CR]
Detail
Get setting status for screen such as Ceiling / Rear.
Acceptable
±%1² [CR]
%1
±11² = Normal Screen Setting
±10² = Top and Bottom reversal setting (Rear
Ceiling On)
±01² = Left and Right reversal setting (Rear On)
±00² = Top / Bottom and Left / Right reversal setting (Ceiling On)
Response
Unacceptable
±?² [CR]