Canon LV-7225 Basic_Serial_Command_Codes - Page 20

Temp Read Command

Page 20 highlights

Basic Serial Command Functional Specification Page 19 of 19 7.7. Temp Read Command Command "CR6" [CR] Detail Get the temperature inside a Projector. When some temperature sensors are installed in the Projector, it is possible to know the temperature all at once. Acceptable "%1_%2_%3" [CR] Response %1 = Temperature, sensor 1 %2 = Temperature, sensor 2 %3 = Temperature, sensor 3 Temperature data form shows as 00.0. When the temperature sinks to -, the first character is "-" like "-05.5" [CR]. When cannot return the temperature data due to hardware %1 %2 %3 problems, the first character is "E" like"E00.0" [CR]. When the status is Standby or it is 10 seconds after Power On, depend on Projectors; temperature may approach critical temperature due to ballast lamp's residual heat. So, when the status is Standby or it is 10 seconds after Power On, the process for the abnormal temperature is not executed. The temperature data is " ----" at the time. When some temperature sensors are installed, the Projector sends command continuously. "_31.5__35.2__33.4" [CR] There is the first sensor's information, and after one space, there is the second sensor's information. Unacceptable "?" [CR]

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Basic Serial Command Functional Specification
Page 19 of 19
7.7. Temp Read Command
Command
±CR6² [CR]
Detail
Get the temperature inside a Projector.
When some temperature sensors are installed in the Projector, it is possible to know
the temperature all at once.
Acceptable
±%1_%2_%3² [CR]
%1
%2
%3
%1 = Temperature, sensor 1
%2 = Temperature, sensor 2
%3 = Temperature, sensor 3
Temperature data form shows as 00.0.
When the temperature sinks to -, the first character is ±-² like ±-05.5²
[CR].
When cannot return the temperature data due to hardware
problems, the first character is ±E² like²E00.0² [CR].
When the status is Standby or it is 10 seconds after Power On,
depend
on
Projectors;
temperature
may
approach
critical
temperature due to ballast lamp³s residual heat. So, when the status
is Standby or it is 10 seconds after Power On, the process for the
abnormal temperature is not executed. The temperature data is
±
----² at the time.
When some temperature sensors are installed, the Projector sends
command continuously. ±_31.5__35.2__33.4² [CR]
There is the first sensor³s information, and after one space, there is
the second sensor³s information.
Response
Unacceptable
±?² [CR]