Canon LV-S4 Serial Functional Specification - Page 12
ON Start Disable Command, Power Management Ready Command, Power Management OFF Command, Power
View all Canon LV-S4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
SERIAL FUNCTIONAL SPECIFICATION Page 11 of 18 7.30. ON Start Disable Command Command "C29" [CR] Detail Clear to Power ON Start This status is stored in EEPROM, so even if turning off and on. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 7.31. Power Management Ready Command Command "C2A" [CR] Detail Set Power Management to Ready This status is stored in EEPROM, so even if turning off and on. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 7.32. Power Management OFF Command Command "C2B" [CR] Detail Set Power Management to OFF mode. This status is stored in EEPROM, and even if turning OFF and ON. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 7.33. Power Management Shut Down Command Command "C2E" [CR] Detail Set Power Management to Shut down mode. This status is stored in EEPROM, and even if turning OFF and ON. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 7.34. D.Zoom + Command Command "C30" [CR] Detail Moving on to Digital Zoom mode and make the screen image bigger. This command works the same as the Remote control's "D.ZOOM UP" button. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 7.35. D.Zoom - Command Command "C31" [CR] Detail Moving on to Digital Zoom mode and make the screen image smaller. This command works the same as the Remote control's "ZOOM DOWN" button. Response Acceptable [ACK] [CR] Unacceptable "?" [CR]