Canon LV-S4 Serial Functional Specification - Page 18
[CR], 04 [CR], 4. Input Mode Read Command, Lamp Time Read Command
View all Canon LV-S4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
SERIAL FUNCTIONAL SPECIFICATION Page 17 of 18 9) "24" [CR] Status: Processing Power Save / Cooling Down When Power Management function is ON in setting menu and there is no signal for 5 minutes, it moves on to Power Save/Cooling Down after tuning off the lamps. (During this process, Green LED is OFF.) The control command is invalid After this Power Save/Coolign Down continues for about 90 seconds, it moves on to Power Save.(Green LED flashes.) Status: No signal Response "00" Power Save / Cooling Down "24" Power Save "04" After 5 minutes with no signal after about 90 seconds 10) "04" [CR] Status of Power Save When the Power Management function is ON in setting menu, and there is no signal for 5 minutes, it moves on to PowerSave status after PowerSave and Cooling Down. Moving on to the status of Power On is the same action as moving on to the Power On from the status of normal stand by. ・Power ON Command:"C00"[CR move on the status of power on ・Power OFF Command:"C01"[CR move on the status of stand by Moving on to the status of Power On is the same action as moving on to the Power On from the status of normal stand by. 8.4. Input Mode Read Command Command "CR1" [CR] Detail Get selected Input No. Acceptable "%1" [CR] Response %1 "1" = Computer is selected "3" = Video is selected Unacceptable "?" [CR] 8.5. Lamp Time Read Command Command "CR3" [CR] Detail Get total lamp running hours. Acceptable "%1" [CR] Response %1 Show as 4 digits Ex.: "0410"[CR] !410 hours Unacceptable "?" [CR]