Canon REALiS LCOS WUX6000 WUX6000 Command List - Page 50
Fltwrn
View all Canon REALiS LCOS WUX6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
WUX6000 User Commands FLTWRN Air filter cleaning warning Format Setting Reference Command Response Command Response FLTWRN= i:OK GET= FLTWRN g: FLTWRN= Note: See "Error list" for any response other than the above. FLTWRN= Parameter OFF Turned off ON Turned on Meaning Environment Power mode restriction Input LAN RS-232C SL0 SL1 SL3 PM ON ST PM ON D-RGB A-RGB COMP HDMI LAN USB None No No No No Yes No No Yes Yes Yes Yes Yes Yes Yes Yes Example (Setting) >FLTWRN=OFF < i:OK (Reference) >GET=FLTWRN < g:FLTWRN=OFF Note: '>' indicates a command; '
WUX6000
User Commands
-47-
FLTWRN
Air filter cleaning warning
Format
Setting
Command
FLTWRN=<Filter warning parameter:ID>
Response
i:OK
Reference
Command
GET= FLTWRN
Response
g: FLTWRN=<Filter warning parameter:ID>
Note: See "Error list" for any response other than the above.
FLTWRN=<Filter warning parameter:ID>
Parameter
Meaning
OFF
Turned off
ON
Turned on
Environment
Power mode restriction
Input
LAN
RS-232C
SL0
SL1
SL3
PM
ON
ST
PM
ON
D-RGB
A-RGB
COMP
HDMI
LAN
USB
None
No
No
No
No
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Example
(Setting)
>FLTWRN=OFF
< i:OK
(Reference)
>GET=FLTWRN
< g:FLTWRN=OFF