Compaq 5500R Service Guide - Page 102
Array Configuration Utility ACU to con the, Run the Array Configuration Utility ACU.
UPC - 743172768186
View all Compaq 5500R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 102 highlights
3-44 Compaq ProLiant 5500 and 5500R Maintenance and Service Guide Table 3-21 ADU Diagnostic Messages continued Message Description Loose cable detected logical drives may be marked FAILED until corrected Controller unable to communicate with one or more physical drives, probably because of a cabling problem. Logical drives may be in a FAILED state until the condition is corrected, preventing access to data on the controller. Mirror data miscompare Data was found at reinitialization in the posted write memory; however, the mirror data compare test failed resulting in data being marked as invalid. Data loss is possible. No configuration for accelerator board The array accelerator board has not been configured. NVRAM configuration present, controller not detected EISA nonvolatile RAM has a configuration for an array controller but there is no board in this slot. Either a board has been removed from the system or a board has been placed in the wrong slot. RIS copies between drives do not match Drives on controller contain copies of RIS which do not match. SCSI Port x Drive ID x has exceeded threshold(s) Monitor and performance threshold for this drive has been violated. SCSI Port x Drive ID x is not stamped for monitoring Drive has not been stamped with monitor and performance features. SCSI Port x Drive ID x RIS copy mismatch SCSI Port x Drive ID x failed - REPLACE (failure message) SCSI Port x Drive ID x firmware needs upgrading Copies of RIS on drive do not match. ADU found drive needs to be replaced. Drive firmware is below recommended version. Recommended Action Check all controller and drive cable connections. Replace the array accelerator board. If the array accelerator board is present, run the Array Configuration Utility (ACU) to configure the board. Place the array controller in the proper slot or run the System Configuration Utility to reconfigure nonvolatile RAM to reflect the removal or new position. Upgrade ADU to the most recent version. Check for the particular threshold that has been violated. Run the Array Configuration Utility (ACU). Changing the configuration and saving should cause ACU to stamp drive with monitor and performance features. To do this without destroying the current configuration, change array accelerator size and save configuration. Change array accelerator back to original size and save again. Drive may need to be replaced. Check for other errors. Replace drive or correct condition that caused error. Run Options ROMPaq to upgrade drive to latest firmware revision. continued For use with Pentium II and Pentium III Xeon processor-based servers only