Compaq 5500R Service Guide - Page 98
Message, Description, Recommended Action, Do not, Restart the system. Run the Array Configuration - 5500 driver
UPC - 743172768186
View all Compaq 5500R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 98 highlights
3-40 Compaq ProLiant 5500 and 5500R Maintenance and Service Guide Table 3-21 ADU Diagnostic Messages continued Message Description Controller is not configured Controller is not configured. If controller was previously configured and you change drive locations, there may be a problem with placement of the drives. ADU examines each physical drive and looks for drives that have been moved to a different drive bay. Controller reported POST error. Error Code: x The controller returned an error from its internal Power-On Self Tests. Controller restarted with a signature of zero ADU did not find a valid configuration signature to use to get the data. Nonvolatile RAM may not be present (unconfigured) or the signature present in nonvolatile RAM may not match the signature on the controller. Disable command issued Posted-writes have been disabled by the issuing of the Accelerator Disable command. This occurred because of an operating system device driver. Drive (bay) X firmware needs upgrading Firmware on this physical drive is below the latest recommended version. Drive (bay) X has insufficient capacity for its configuration Drive has insufficient capacity to be used in this logical drive configuration. Drive (bay) X has invalid M&P stamp Physical drive has invalid monitor and performance data. Drive (bay) X has loose cable The array controller could not communicate with this drive at power-up. This drive has not previously failed. Drive (bay) X is a replacement drive This drive has been replaced. This message displays if a drive is replaced in a fault tolerant logical volume. Recommended Action Look for messages indicating which drives have been moved. If none appear and drive swapping did not occur, run the Array Configuration Utility to configure the controller and the System Configuration Utility to configure nonvolatile RAM. Do not run either Utility if you believe drive swapping has occurred. Replace the controller. Run the System Configuration Utility to configure the controller and nonvolatile RAM. Restart the system. Run the Array Configuration Utility to reinitialize the array accelerator board. Run the Options ROMPaq Utility to upgrade the drive firmware to the latest revision. Replace this drive with a larger capacity drive. Run the System Configuration Utility to properly initialize this drive. Check all cable connections first. The cables could be bad, loose, or disconnected. Turn on the system and attempt to reconnect signal/power cable to the drive. If this does not work, replace the cable. If that does not work, the drive may need to be replaced. If the replacement was intentional, allow the drive to rebuild. continued For use with Pentium II and Pentium III Xeon processor-based servers only