Compaq 5500R Service Guide - Page 78
Drives Disabled due
UPC - 743172768186
View all Compaq 5500R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 78 highlights
3-20 Compaq ProLiant 5500 and 5500R Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps L=Long S=Short 1798-Drive Array - None Array Accelerator Write Error Occurred. Array Accelerator is disabled. 1799-Drive Array - None Drive(s) Disabled due to Array Accelerator Data Loss. Select "F1" to continue with logical drives disabled. Select "F2" to accept data loss and to re- enable logical drives. Beeps only: 2 Long 2L Beeps only: 2 Long + 2 Short 2L, 2S (Run System None Configuration Utility - F10 key) (RESUME - F1 key) None Probable Source of Problem Hard parity error while writing data to posted-writes memory. Recommended Action Enable Array Accelerator. Volume failed due to loss of data in posted-writes memory. Press F1 to continue with logical drives disabled or F2 to accept data loss and re-enable logical drive. No valid memory is present in the system. Power is cycled. Temperature too hot. Processor fan either not installed or not spinning. A configuration error occurred during POST. Replace failed memory with valid memory. Check fans. Press F10 to run System Configuration Utility. As indicated to continue. Press F1 For use with Pentium II and Pentium III Xeon processor-based servers only