Disconnect the pointing device cable from the connector on the top cover, Remove the keyboard.
View all Compaq Armada m700 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 96 highlights
5. Release the Zero Insertion Force (ZIF) connector to which the keyboard cable is connected (Figure 5-19). 6. Disconnect the keyboard cable from the connector on the system board . 7. Release the ZIF connector to which the pointing device cable is connected (EasyPoint IV models only). 8. Disconnect the pointing device cable from the connector on the top cover (EasyPoint IV models only). Figure 5-19. Disconnecting the Pointing Device and the Keyboard Cables 9. Remove the keyboard. Reverse the above procedure to install the keyboard. Removal and Replacement Procedures 5-21
Removal and Replacement Procedures
5-21
5. Release the Zero Insertion Force (ZIF) connector to which the keyboard cable is
connected
➊
(Figure 5-19).
6. Disconnect the keyboard cable from the connector on the system board
➋
.
7. Release the ZIF connector to which the pointing device cable is connected
➌
(EasyPoint IV models only).
8. Disconnect the pointing device cable from the connector on the top cover
➍
(EasyPoint IV models only).
Figure 5-19.
Disconnecting the Pointing Device and the Keyboard Cables
9. Remove the keyboard.
Reverse the above procedure to install the keyboard.