Page 66 highlights
3-14 Diagnostic Tools 1782-Disk Controller None Failure 1784-Drive Array Drive Failure, Physical Drive 1785-Drive Array not Configured None None Hard disk drive circuitry error. Defective drive and/or cables. Configuration error. Run Diagnostics. Replace failed assembly as indicated or contact your service provider. Check for loose cables. Replace defective drive X and/or cable(s). Run the System Configuration Utility and correct. Continued
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3-14
Diagnostic Tools
1782-Disk Controller
Failure
None
Hard disk drive circuitry
error.
Run Diagnostics.
Replace failed
assembly as indicated
or contact your service
provider.
1784-Drive Array
Drive Failure,
Physical Drive
None
Defective drive and/or
cables.
Check for loose cables.
Replace defective
drive
X
and/or cable(s).
1785-Drive Array
not Configured
None
Configuration error.
Run the System
Configuration Utility
and correct.