Compaq ProLiant 2500 Compaq ProLiant 2500 Family of Servers Maintenance and Se - Page 81
Fixed Disk Drive Test Error Codes, Table 3-11
View all Compaq ProLiant 2500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
3-29 Table 3-11 Fixed Disk Drive Test Error Codes Error Code Description Recommended Action 1700-xx 1701-xx 1702-xx 1703-xx 1704-xx 1705-xx 1708-xx 1709-xx 1710-xx 1715-xx 1716-xx 1717-xx 1719-xx 1736-xx 1799-xx Fixed disk ID drive types test failed Fixed disk format test failed Fixed disk read test failed Fixed disk write/read/compare test failed Fixed disk random seek test failed Fixed disk controller test failed Fixed disk format bad track test failed Fixed disk reset controller test failed Fixed disk park head test failed Fixed disk head select test failed The following steps apply to error codes 1700-xx through 1799-xx: 1. Run the Configuration Utility and verify the drive type. 2. Replace the fixed disk drive signal and power cables and retest. 3. Replace the fixed disk drive controller and retest. 4. Replace the fixed disk drive and retest. Fixed disk conditional format test failed 5. Replace the system board Fixed disk ECC* test failed and retest. Fixed disk drive power mode test failed Drive Monitoring failed Invalid fixed disk drive type failed * Error Checking and Correcting Error Code Table 3-12 CD-ROM Drive Test Error Codes Description Recommended Action Compaq ProLiant 2500 Family of Servers Maintenance and Service Guide