Compaq ProLiant 2500 Compaq ProLiant 2500 Servers Installation Guide - Page 49
Drive Installation Guidelines
View all Compaq ProLiant 2500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
3-21 Figure 3-16. Installing Hard Drive and Blank Panel CZR-049.EPS Drive Installation Guidelines The following guidelines should be noted when adding SCSI hard drives: A maximum of five SCSI devices may be added per controller. The SCSI ID for each hot-pluggable hard drive is set as the bay number (Bay 0 = SCSI ID 0). If only one SCSI hard drive is used, it should be installed in the lowest numbered bay. Compaq SCSI non-hot-plug cables for the Compaq ProLiant 2500 are terminated. Be sure to remove all terminating jumpers from third-party SCSI devices. Run System Configuration Utility after installing a drive. SCSI hard drives on the Integrated Wide-Ultra SCSI Controller on the PCI Bus must be either internal or in an external storage system, but not both. Compaq ProLiant 2500 Servers Installation Guide