ADU Error Messages Table D-1: Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action Storage enclosure on SCSI bus X indicated an overheated condition. The external storage unit is generating a temperature alert. 1. Be sure that all fans are connected and operating properly. SOLUTION: Make sure all cooling fans are operating properly. Also be sure the operating environment of storage enclosure is within temperature specifications. 2. Be sure that the operating environment of the storage unit is within specifications. 3. For better airflow, remove any dust buildup from fans or other areas. 4. Check your serverspecific user documentation for allowable temperature specifications and additional tips. 5. If none of the previous steps solve this problem, replace the fan. Storage enclosure on SCSI bus X is unsupported with its current firmware version. The firmware version of the external storage unit is not supported. Upgrade the firmware. SOLUTION: Upgrade the firmware version on the storage enclosure. Storage enclosure on SCSI bus X indicated that the fan failed. The cooling fan located in the external storage unit has experienced a failure. Replace the fan. SOLUTION: Replace the fan. continued D-18 HP Servers Troubleshooting Guide