D-Link DGS-3630-52PC User Manual - Page 153

Trace Route, Length, Stop Time, Start, IPv4 Ping, IPv4 Ping Result, Tools > Trace Route

Page 153 highlights

DGS-3630 Series Layer 3 Stackable Managed Switch Web UI Reference Guide Parameter Length Stop Time Description Enter the length value here. This specifies the number of data bytes to send. The default value is 56, which translates into 64 ICMPv6 data bytes when combined with the 8 bytes of ICMPv6 header data. It does not include any VLAN or IEEE 802.1Q tag length. The range is from 1 to 1420 bytes. Enter the stop time value here. This specifies to stop the ping after the amount of times entered here. If this value is configured as 0, then the ping can only be stopped by clicking the Stop button manually. The range is from 0 to 99. Click the Start button to initiate the Ping Test for each individual section. After clicking the Start button in IPv4 Ping section, the following IPv4 Ping Result section will appear: Figure 11-37 Ping (Start) Window Click the Stop button to halt the Ping Test. Click the Back button to return to the IPv4 Ping section. Trace Route The trace route page allows the user to trace a route between the Switch and a given host on the network. To view the following window, click Tools > Trace Route, as shown below: Figure 11-38 Trace Route Window 146

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184

DGS-3630 Series Layer 3 Stackable Managed Switch Web UI Reference Guide
146
Parameter
Description
Length
Enter the length value here. This specifies the number of data bytes to send.
The default value is 56, which translates into 64 ICMPv6 data bytes when
combined with the 8 bytes of ICMPv6 header data. It does not include any
VLAN or IEEE 802.1Q tag length. The range is from 1 to 1420 bytes.
Stop Time
Enter the stop time value here. This specifies to stop the ping after the amount
of times entered here. If this value is configured as 0, then the ping can only be
stopped by clicking the
Stop
button manually. The range is from 0 to 99.
Click the
Start
button to initiate the Ping Test for each individual section.
After clicking the
Start
button in
IPv4 Ping
section, the following
IPv4 Ping Result
section will appear:
Figure 11-37 Ping (Start) Window
Click the
Stop
button to halt the Ping Test.
Click the
Back
button to return to the IPv4 Ping section.
Trace Route
The trace route page allows the user to trace a route between the Switch and a given host on the network.
To view the following window, click
Tools > Trace Route
, as shown below:
Figure 11-38 Trace Route Window