D-Link DIS-2650AP Product Manual - Page 11
Grounding the Device, Using the Terminal Connections
View all D-Link DIS-2650AP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Basic Installation Grounding the Device To use the DIS-2650AP safely, it needs to be grounded. Please complete these steps before powering on the device. 1. Remove the grounding screw from the top of the DIS-2650AP and place the grounding cable lug ring on top of the grounding screw opening. 2. Insert the grounding screw back into the grounding screw opening and use a screwdriver to tighten the grounding screw, securing the grounding cable to the DIS-2650AP. 3. Attach the terminal lug ring at the other end of the grounding cable to an appropriate grounding source. Powering the Device The DIS-2650AP can be powered with an 802.3at PoE source or by using the built-in terminal adapter. This allows dual power inputs using wires from the power source(s) to be screwed into the terminal connections. Using the Terminal Connections 1. Before continuing, consult the diagram below to decide which wires from the power source need to connect to which contacts on the terminal block. Note that two power sources can be used; one inserted into V1-/V1+ (labeled PWR 1) and the other inserted into V2-/V2+ (labeled PWR2). 11