Dell DAE2-ATA Hardware Reference - Page 53

Replacing an LCC Module, Removing an LCC, CAUTION

Page 53 highlights

Servicing a DAE2 Replacing an LCC Module ! CAUTION Handle an LCC gently and use an ESD wristband. Do not remove a faulty LCC until you have a replacement module available. A DAE2 must have at least one LCC installed while it is powered up. Do not remove both LCCs while the disk enclosure is powered up. Always replace an LCC with another of the same model; do not mix Fibre Channel and ATA components in the same enclosure. (An "ATA Ctlr" label on the module bulkhead identifies the ATA LCC.) Removing an LCC 1. Gently press the connector latches to release them as you remove the copper cables connected to the LCC, as shown in Figure 3-10. Note where the cable(s) connect to the LCC; you will need to reconnect them to the replacement LCC. PRI Connector To other FC device Figure 3-10 Removing a Copper Cable from an LCC EMC2782 Replacing an LCC Module 3-15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

Replacing an LCC Module
3-15
Servicing a DAE2
Replacing an LCC Module
CAUTION
!
Handle an LCC gently and use an ESD wristband. Do not remove a
faulty LCC until you have a replacement module available.
A DAE2 must have at least one LCC installed while it is powered up. Do not
remove both LCCs while the disk enclosure is powered up.
Always replace an LCC with another of the same model; do not mix Fibre
Channel and ATA components in the same enclosure. (An "ATA Ctlr" label on
the module bulkhead identifies the ATA LCC.)
Removing an LCC
1.
Gently press the connector latches to release them as you remove
the copper cables connected to the LCC, as shown in Figure 3-10.
Note where the cable(s) connect to the LCC; you will need to reconnect
them to the replacement LCC.
Figure 3-10
Removing a Copper Cable from an LCC
EMC2782
To other FC device
PRI
Connector