Dell External OEMR XL R210II Technical Guide - Page 72

Chipset, Control Panel, iDRAC6 Enterprise

Page 72 highlights

Dell TPM Binding EEPROM (on China planar only) iDRAC6 SDRAM iDRAC6 FRU iDRAC6 Boot Block Flash Trusted Platform Module Chipset Locked by BIOS from physical access by anyone after boot n/a writes controlled by iDRAC embedded OS iDRAC embedded OS control of the write protection SW write protected Not applicable, BIOS control only AC cycle for BMC OS and reset/power off server for VGA frame buffer EPPID is not clearable Not possible with any utilities or applications and iDRAC does not function as expected if corrupted/removed. Lifecycle log is clearable only in a factory environment; System Event Log is user clearable F2 Setup option CMOS Control Panel N/A, BIOS only control Planar NVRAM_CLR jumper or by removal of AC cord, cover, and coin cell battery, then waiting 30 seconds prior to replacement of battery, cover and AC cord.; F2 system setup option is used to restore defaults Internal USB OS control OS control format iDRAC6 Enterprise vFlash Media write protection switch or OS control iDRAC-based format, local OS format, deleted, or card removed and formatted on a client 72 PowerEdge R210 Technical Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

Dell
72
PowerEdge R210 Technical Guide
TPM Binding
EEPROM (on
China planar
only)
Locked by
BIOS from
physical
access by
anyone after
boot
Not applicable, BIOS control only
iDRAC6 SDRAM
n/a
AC cycle for BMC OS and reset/power off server for VGA
frame buffer
iDRAC6 FRU
writes
controlled by
iDRAC
embedded OS
EPPID is not clearable
iDRAC6 Boot
Block Flash
iDRAC
embedded OS
control of the
write
protection
Not possible with any utilities or applications and iDRAC
does not function as expected if corrupted/removed.
Lifecycle log is clearable only in a factory environment;
System Event Log is user clearable
Trusted
Platform Module
SW write
protected
F2 Setup option
Chipset
CMOS
N/A, BIOS
only control
Planar NVRAM_CLR jumper or by removal of AC cord,
cover, and coin cell battery, then waiting 30 seconds prior
to replacement of battery, cover and AC cord.; F2 system
setup option is used to restore defaults
Control Panel
Internal USB
OS control
OS control format
iDRAC6 Enterprise
vFlash
Media write
protection
switch or OS
control
iDRAC-based format, local OS format, deleted, or card