Dell PowerConnect B-RX Multi-Service IronWare Software R02.7.02a Release Notes - Page 28

show version, copy tftp mbridge, MBRIDGE, copy slot1 | slot2 mbridge

Page 28 highlights

Software image installed on BigIron RX 02.5.00 02.5.00a 02.5.00b 02.5.00c 02.5.00d 02.5.00e 02.5.00f 02.5.00g 02.5.00h 02.5.00i 02.5.00j 02.6.00 02.6.00a 02.6.00b 02.6.00c 02.6.00d 02.6.00e 02.7.00 02.7.01 02.7.01a 02.7.01b 02.7.02 02.7.02a FPGA image SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE Compatible FPGA version 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 To upgrade the MBRIDGE FPGA image on a BigIron RX management module, you must perform the following general steps: 1. Determine the versions of the images currently installed on the BigIron RX management module using the show version command. 1. Place the new MBRIDGE FPGA image on a TFTP server to which the BigIron RX system has access or on a PCMCIA flash card inserted in slot 1 or 2. 2. Copy the MBRIDGE FPGA image from the TFTP server or a flash card in slot 1 or 2 to all management modules or a management module in a specified chassis slot. To perform this step, enter one of the following commands at the Privileged EXEC level of the CLI (example: BigIron RX#): • copy tftp mbridge MBRIDGE • copy slot1 | slot2 mbridge MBRIDGE 3. After the MBRIDGE upgrade is complete, the management module must be reloaded. 4. Verify that the MBRIDGE image(s) have been successfully copied to the specified interface module(s) by entering the following command at any level of the CLI: • show version Check for the MBRIDGE image version numbers in the output. See MBRIDGE. IronWare Software Release 02.7.02a for Brocade BigIron RX Series Swtches Release Notes v 1.0 Page 28 of 46

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

IronWare Software Release 02.7.02a
for Brocade BigIron RX Series Swtches
Release Notes v 1.0
Page 28 of 46
Software image
installed on
BigIron RX
FPGA
image
Compatible FPGA
version
02.5.00
SBRIDGE
6
02.5.00a
SBRIDGE
6
02.5.00b
SBRIDGE
6
02.5.00c
SBRIDGE
6
02.5.00d
SBRIDGE
6
02.5.00e
SBRIDGE
6
02.5.00f
SBRIDGE
6
02.5.00g
SBRIDGE
6
02.5.00h
SBRIDGE
6
02.5.00i
SBRIDGE
6
02.5.00j
SBRIDGE
6
02.6.00
SBRIDGE
6
02.6.00a
SBRIDGE
6
02.6.00b
SBRIDGE
6
02.6.00c
SBRIDGE
6
02.6.00d
SBRIDGE
6
02.6.00e
SBRIDGE
6
02.7.00
SBRIDGE
6
02.7.01
SBRIDGE
6
02.7.01a
SBRIDGE
6
02.7.01b
SBRIDGE
6
02.7.02
SBRIDGE
6
02.7.02a
SBRIDGE
6
To upgrade the MBRIDGE FPGA image on a BigIron RX management module, you must perform the
following general steps:
1.
Determine the versions of the images currently installed on the BigIron RX management module
using the
show version
command.
1.
Place the new MBRIDGE FPGA image on a TFTP server to which the BigIron RX system has
access or on a PCMCIA flash card inserted in slot 1 or 2.
2.
Copy the MBRIDGE FPGA image from the TFTP server or a flash card in slot 1 or 2 to all
management modules or a management module in a specified chassis slot. To perform this step,
enter one of the following commands at the Privileged EXEC level of the CLI (example: BigIron
RX#):
copy tftp mbridge
<TFTP-server-ip-addr> <image-name>
MBRIDGE
copy slot1 | slot2 mbridge
<image-name>
MBRIDGE
3.
After the MBRIDGE upgrade is complete, the management module must be reloaded.
4.
Verify that the MBRIDGE image(s) have been successfully copied to the specified interface
module(s) by entering the following command at any level of the CLI:
show version
Check for the MBRIDGE image version numbers in the output. See MBRIDGE.