Dell PowerConnect B-RX Multi-Service IronWare Software R02.7.02a Release Notes - Page 37

Syslog message examples, Event, Description

Page 37 highlights

Syslog message examples Event Description Jan 8 11:48:29:E:System: ALARM:LP3/TM1 has shutdown (TM Q Stuck: LP3/TM1 (Queue 1024, Size 50331648, Credit 2047, RdPtr 0x0) (shutdown))] Jan 8 11:48:19:E:System: ALARM:LP3/TM1 re-initialized (TM Q Stuck: LP3/TM1 (Queue 1024, Size 50331648, Credit 2047, RdPtr 0x0) (QDP reinit)) Jan 8 11:48:19:E:System: ALARM:LP3/TM1 QDP reinitialized (TM Q Stuck: LP3/TM1 (Queue 1024, Size 50331648, Credit 2047, RdPtr 0x0) (QDP reinit)) TM queue scanner Blocked traffic queues in the TM. Dec 31 13:51:42:E:System: ALARM:LP1/TM1 has shutdown (LP1/NP1 TCAM failure (shutdown)) TCAM scan Corruption on the TCAM. Jan 8 08:59:29:E:System: ALARM:LP3/NP2 packet path diagnostic failure PKT path scan Problems in the packet path from the LP CPU to the TM to the NP then back to the CPU. Sep 13 15:01:29:E:System: ALARM:FE Read-Write Test Error: SNM4/FE1 Reg 0x14, Read 0x48000000 != Written 0x0 Switch fabric A failure has occurred on the element read/write specified switch fabric module error Sep 13 15:01:29:E:System: ALARM: LP9/TM2 has shutdown (TM DRAM CRC: LP9/TM2 (Reg: 0xa50c, Value: 0x7) (shutdown)) TM ingress DRAM A failure was detected on the CRC error ingress DRAM. The failed device was shutdown Sep 13 15:01:29:E:System: ALARM: LP16/TM1 re-initialized (TM TX BUFFER Stuck: LP16/TM1 (Reg: 0x400000b4, Value: 0x1de) (reinit)) TM egress buffer stuck error A blocked Traffic Manager egress buffer was detected and recovered NOTE: Brocade Technical Support may guide you in using SYSMON commands to obtain additional information. Do not use these commands without guidance from technical support. IronWare Software Release 02.7.02a for Brocade BigIron RX Series Swtches Release Notes v 1.0 Page 37 of 46

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

IronWare Software Release 02.7.02a
for Brocade BigIron RX Series Swtches
Release Notes v 1.0
Page 37 of 46
Syslog message examples
Event
Description
Jan
8 11:48:29:E:System:
ALARM:LP3/TM1 has shutdown
(TM Q Stuck: LP3/TM1
(Queue
1024, Size 50331648, Credit
2047, RdPtr 0x0)
(shutdown))]
Jan
8 11:48:19:E:System:
ALARM:LP3/TM1 re-initialized
(TM Q Stuck: LP3/TM1
(Queue
1024, Size 50331648, Credit
2047, RdPtr 0x0) (QDP
reinit))
Jan
8 11:48:19:E:System:
ALARM:LP3/TM1 QDP re-
initialized (TM Q Stuck:
LP3/TM1
(Queue 1024, Size
50331648, Credit 2047, RdPtr
0x0) (QDP reinit))
TM queue scanner
Blocked traffic queues in the TM.
Dec 31 13:51:42:E:System:
ALARM:LP1/TM1 has shutdown
(LP1/NP1 TCAM failure
(shutdown))
TCAM scan
Corruption on the TCAM.
Jan
8 08:59:29:E:System:
ALARM:LP3/NP2 packet path
diagnostic failure
PKT path scan
Problems in the packet path from
the LP CPU to the TM to the NP
then back to the CPU.
Sep 13 15:01:29:E:System: ALARM:FE
Read-Write Test Error: SNM4/FE1 Reg
0x14, Read 0x48000000 != Written 0x0
Switch fabric
element read/write
error
A failure has occurred on the
specified switch fabric module
Sep 13 15:01:29:E:System: ALARM:
LP9/TM2 has shutdown (TM DRAM
CRC: LP9/TM2
(Reg: 0xa50c, Value:
0x7) (shutdown))
TM ingress DRAM
CRC
error
A failure was detected on the
ingress DRAM.
The failed
device was shutdown
Sep 13 15:01:29:E:System: ALARM:
LP16/TM1 re-initialized (TM TX
BUFFER Stuck: LP16/TM1
(Reg:
0x400000b4, Value: 0x1de) (reinit))
TM egress buffer
stuck error
A blocked Traffic Manager
egress buffer was detected and
recovered
NOTE
: Brocade Technical Support may guide you in using SYSMON commands to obtain additional
information. Do not use these commands without guidance from technical support.