Dell PowerConnect B-RX Multi-Service IronWare Software R02.8.00 Release Notes - Page 23

Rebooting the management module, on BigIron RX

Page 23 highlights

Software image installed on BigIron RX 02.6.00a through 02.6.00e 02.7.00 02.7.01 02.7.01a through 02.7.01b 02.7.02 02.7.02a through 02.7.02h 02.7.03 through 02.7.03a 02.8.00 FPGA image SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE SBRIDGE Compatible FPGA version 6 6 6 6 6 6 6 6 To upgrade the MBRIDGE FPGA image on the BigIron RX management module, perform the following general steps: 1. Determine the versions of the images currently installed on the BigIron RX management module using the show version command. 2. Place the new MBRIDGE FPGA image on a TFTP server to which the BigIron RX system has access or on a PCMCIA flash card inserted in slot 1 or slot 2. 3. Copy the MBRIDGE FPGA image from the TFTP server or a flash card in slot 1 or slot 2 to all management modules or a management module in a specified chassis slot. To perform this step, enter one of the following commands at the Privileged EXEC level of the CLI (For example: BigIron RX#): • copy tftp mbridge MBRIDGE • copy slot1 | slot2 mbridge MBRIDGE 4. After the MBRIDGE upgrade is complete, the management module must be reloaded. 5. Verify that the MBRIDGE image(s) have been successfully copied to the specified interface module(s) by entering the following command at any level of the CLI: BigIron RX# show version Check for the MBRIDGE image version numbers in the output. See MBRIDGE. Rebooting the management module After upgrading one or more software images on the management or interface module, you must reboot the management module. After the management module reboots, it in turn reboots the interface modules. To reboot the management module, enter one of the following commands: • reload (this command boots from the default boot source, which is the primary code flash) • boot system flash primary | secondary During the management module reboot, the following synchronization events occur: • If you have a standby management module, the active management module compares the standby module's monitor, primary, and secondary images to its own. If you have updated these images on the active module, the active module automatically synchronizes the standby module's images with its own. IronWare Software Release 02.8.00 for Brocade BigIron RX Series Swtches Release Notes v 1.0 Page 23 of 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37

IronWare Software Release 02.8.00
for Brocade BigIron RX Series Swtches
Release Notes v 1.0
Page 23 of 37
Software image installed
on BigIron RX
FPGA image
Compatible FPGA
version
02.6.00a through 02.6.00e
SBRIDGE
6
02.7.00
SBRIDGE
6
02.7.01
SBRIDGE
6
02.7.01a through 02.7.01b
SBRIDGE
6
02.7.02
SBRIDGE
6
02.7.02a through 02.7.02h
SBRIDGE
6
02.7.03 through 02.7.03a
SBRIDGE
6
02.8.00
SBRIDGE
6
To upgrade the MBRIDGE FPGA image on the BigIron RX management module, perform the following
general steps:
1.
Determine the versions of the images currently installed on the BigIron RX management module
using the
show version
command.
2.
Place the new MBRIDGE FPGA image on a TFTP server to which the BigIron RX system has access
or on a PCMCIA flash card inserted in slot 1 or slot 2.
3.
Copy the MBRIDGE FPGA image from the TFTP server or a flash card in slot 1 or slot 2 to all
management modules or a management module in a specified chassis slot. To perform this step, enter
one of the following commands at the Privileged EXEC level of the CLI (For example:
BigIron
RX#
):
copy tftp mbridge
<TFTP-server-ip-addr> <image-name>
MBRIDGE
copy slot1 | slot2 mbridge
<image-name>
MBRIDGE
4.
After the MBRIDGE upgrade is complete, the management module must be reloaded.
5.
Verify that the MBRIDGE image(s) have been successfully copied to the specified interface
module(s) by entering the following command at any level of the CLI:
BigIron RX# show version
Check for the MBRIDGE image version numbers in the output. See
MBRIDGE
.
Rebooting the management module
After upgrading one or more software images on the management or interface module, you must reboot
the management module. After the management module reboots, it in turn reboots the interface modules.
To reboot the management module, enter one of the following commands:
reload
(this command boots from the default boot source, which is the primary code flash)
boot system flash primary | secondary
During the management module reboot, the following synchronization events occur:
If you have a standby management module, the active management module compares the standby
module’s monitor, primary, and secondary images to its own. If you have updated these images on the
active module, the active module automatically synchronizes the standby module’s images with its
own.