Dell PowerEdge C5220 Using the Baseboard Management Controller - Page 14
Table 1-5., Blinking Fault LED Conditions, Index, Sensor Name, Event Triggers, LED Status, Color
![]() |
View all Dell PowerEdge C5220 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
Table 1-4. LED Status LED ID LED Heartbeat LED Color Status Occurrence Note Blue Off Normal status (by IPMI Chassis Identify command or System ID Button) Turn off the ID LED. 1. ipmitool raw 0x00 0x04 0x00 2. ipmitool raw 0x00 0x04 0x00 0x00 Solid On Identify the system Turn on the ID LED. 1.ipmitool raw 0x00 0x04 0x3c 01 Blinking Identify the system with interval 1. IPMI chassis identify command without request data ipmitool raw 0x00 0x04 2. IPMI chassis identify command with only 1 parameter data ipmitool raw 0x00 0x04 0x3c (blink 60 sec) 3. IPMI chassis identify command with 2 parameter data ipmitool raw 0x00 0x04 0x3c 0x00 (blink 60 sec) Green Off BMC is not ready Blinking BMC is ready Table 1-5. Blinking Fault LED Conditions Index Sensor Name Event Triggers 1 CPU Temp • Upper Critical Going High Ambient Temp, • Upper Non-Critical Going High DIMM Temp Rear Temp 1 Rear Temp 2 Rear Temp 3 2 SLED 12V • Upper Critical Going High • Upper Non-Critical Going High 14
![](/manual_guide/products/dell-poweredge-c5220-using-baseboard-management-controllernbsp-923dbc6/14.png)