Dell PowerEdge C5220 Using the Baseboard Management Controller  - Page 14

Table 1-5., Blinking Fault LED Conditions, Index, Sensor Name, Event Triggers, LED Status, Color

Page 14 highlights

Table 1-4. LED Status LED ID LED Heartbeat LED Color Status Occurrence Note Blue Off Normal status (by IPMI Chassis Identify command or System ID Button) Turn off the ID LED. 1. ipmitool raw 0x00 0x04 0x00 2. ipmitool raw 0x00 0x04 0x00 0x00 Solid On Identify the system Turn on the ID LED. 1.ipmitool raw 0x00 0x04 0x3c 01 Blinking Identify the system with interval 1. IPMI chassis identify command without request data ipmitool raw 0x00 0x04 2. IPMI chassis identify command with only 1 parameter data ipmitool raw 0x00 0x04 0x3c (blink 60 sec) 3. IPMI chassis identify command with 2 parameter data ipmitool raw 0x00 0x04 0x3c 0x00 (blink 60 sec) Green Off BMC is not ready Blinking BMC is ready Table 1-5. Blinking Fault LED Conditions Index Sensor Name Event Triggers 1 CPU Temp • Upper Critical Going High Ambient Temp, • Upper Non-Critical Going High DIMM Temp Rear Temp 1 Rear Temp 2 Rear Temp 3 2 SLED 12V • Upper Critical Going High • Upper Non-Critical Going High 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

14
Table 1-5.
Blinking Fault LED Conditions
ID LED
Blue
Off
Normal status (by IPMI
Chassis Identify
command or System ID
Button)
Turn off the ID LED.
1. ipmitool raw 0x00 0x04
0x00
2. ipmitool raw 0x00 0x04
0x00 0x00
Solid On
Identify the system
Turn on the ID LED.
1.ipmitool raw 0x00 0x04 0x3c
01
Blinking
Identify the system with
interval
1. IPMI chassis identify
command without request
data ipmitool raw 0x00 0x04
2. IPMI chassis identify
command with only 1
parameter data ipmitool raw
0x00 0x04 0x3c (blink 60 sec)
3. IPMI chassis identify
command with 2 parameter
data ipmitool raw 0x00 0x04
0x3c 0x00 (blink 60 sec)
Heartbeat
LED
Green
Off
BMC is not ready
Blinking
BMC is ready
Index
Sensor Name
Event Triggers
1
CPU Temp
Upper Critical Going High
Upper Non-Critical Going High
Ambient Temp,
DIMM Temp
Rear Temp 1
Rear Temp 2
Rear Temp 3
2
SLED 12V
Upper Critical Going High
Upper Non-Critical Going High
Table 1-4.
LED Status
LED
Color
Status
Occurrence
Note