Dell PowerEdge C5220 Using the Baseboard Management Controller - Page 57
Table 1-47., Sensory Device Commands, Command, NetFn, Supported, LAN Commands
View all Dell PowerEdge C5220 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
Table 1-47. Sensory Device Commands Command NetFn CMD O/M Get Device SDR Info S/E 20h O Get Device SDR S/E 21h O Reserve Device SDR Repository S/E 22h O Get Sensor Reading Factors S/E 23h O Set Sensor Hysteresis S/E 24h O Get Sensor Hysteresis S/E 25h O Set Sensor Threshold S/E 26h O Get Sensor Threshold S/E 27h O Set Sensor Event Enable S/E 28h O Get Sensor Event Enable S/E 29h O Re-arm Sensor Events S/E 2Ah O Get Sensor Event Status S/E 2Bh O Get Sensor Reading S/E 2Dh M Set Sensor Type S/E 2Eh O Get Sensor Type S/E 2Fh O Set Sensor Reading and Event S/E 30h M Status Supported No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No Yes Table 1-48. LAN Commands Command NetFn CMD O/M Set LAN Configuration Parameters Transport 01h M Get LAN Configuration Parameters Transport 02h M Suspend BMC ARP Transport 03h O Get IP/UDP/RMCP Statistics Transport 04h O NOTE: LAN parameter from 192 to 255 is reserved for OEM parameters. Supported Yes Yes Yes No 57