Dell PowerEdge C5220 Using the Baseboard Management Controller  - Page 54

Table 1-41., BMC Watchdog Timer Commands, Command, NetFn, Supported, Table 1-42., Chassis Commands,

Page 54 highlights

Table 1-40. BMC Device and Messaging Commands Command Master Write-Read I2C Get Channel Cipher Suites Suspend/Resume Payload Encryption Set Channel Security Keys Get System Interface Capabilities NetFn App App App App App CMD 52h 54h 55h 56h 57h Table 1-41. BMC Watchdog Timer Commands Command Reset Watchdog Timer Set Watchdog Timer Get Watchdog Timer NetFn App App App CMD 22h 24h 25h Table 1-42. Chassis Commands Command Get Chassis Capabilities Get Chassis Status Chassis Control Chassis Reset Chassis Identify Set Chassis Capabilities Set Power Restore Policy Get System Reset Cause Set System Boot Options Get System Boot Options Set Front Panel Button Enable Set Power Cycle Interval NetFn Chassis Chassis Chassis Chassis Chassis Chassis Chassis Chassis Chassis Chassis Chassis Chassis CMD 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh O/M M O O O O O/M M M M O/M M M M O O O O O[1] O O O O 54 Supported Yes Yes Yes Yes Yes Supported Yes Yes Yes Supported Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

54
Master Write-Read I2C
App
52h
M
Yes
Get Channel Cipher Suites
App
54h
O
Yes
Suspend/Resume Payload
Encryption
App
55h
O
Yes
Set Channel Security Keys
App
56h
O
Yes
Get System Interface
Capabilities
App
57h
O
Yes
Table 1-41.
BMC Watchdog Timer Commands
Command
NetFn
CMD
O/M
Supported
Reset Watchdog Timer
App
22h
M
Yes
Set Watchdog Timer
App
24h
M
Yes
Get Watchdog Timer
App
25h
M
Yes
Table 1-42.
Chassis Commands
Command
NetFn
CMD
O/M
Supported
Get Chassis Capabilities
Chassis
00h
M
Yes
Get Chassis Status
Chassis
01h
M
Yes
Chassis Control
Chassis
02h
M
Yes
Chassis Reset
Chassis
03h
O
No
Chassis Identify
Chassis
04h
O
Yes
Set Chassis Capabilities
Chassis
05h
O
Yes
Set Power Restore Policy
Chassis
06h
O
Yes
Get System Reset Cause
Chassis
07h
O[1]
Yes
Set System Boot Options
Chassis
08h
O
Yes
Get System Boot Options
Chassis
09h
O
Yes
Set Front Panel Button Enable
Chassis
0Ah
O
Yes
Set Power Cycle Interval
Chassis
0Bh
O
Yes
Table 1-40.
BMC Device and Messaging Commands
Command
NetFn
CMD
O/M
Supported