F8h/2F8h
View all Dell PowerEdge C8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 100 highlights
Option Serial port number (COM1 default) Serial Port Address (3F8h/2F8h default) Serial Port Mode (115200 8,n,1 as default) Flow Control (None default) Redirection After BIOS POST (Always default) Terminal Type (ANSI default) VT-UTF8 Combo Key Support (Enabled default) Description Select a serial port for console redirection. • COM1: Enables console redirection via COM1. See token D7h. • COM2 as SOL: Enables console redirection via COM2. Specifies the base I/O port address of the serial port. • 3F8h/2F8h: Sets the front serial port address as 0x3F8 and internal serial port address as 0x2F8. • COM2 as SOL: Sets the front serial port address as 0x2F8 and internal serial port address as 0x3F8. Select a baud rate for the serial port. Options are [115200 8,n,1], [57600 8,n,1], [38400 8,n,1], [192008,n,1], and [9600 8,n,1]. Select a flow control for console redirection. Options are [None] and [Software]. If set to Always, the console redirection is always active. When Disabled, console redirection is turned off after POST. Select a target terminal type for console redirection. Options are [ANSI], [VT100], and [VT-UTF8]. Enables or disables the VT-UTF8 Combination Key support for ANSI/VT100 terminals. 100 Using the System Setup Program