Dell PowerEdge C8000 Dell PowerEdge C8000 Hardware Owner's Manual - Page 115

Enables the DCU Streamer Prefetcher. default - hpc

Page 115 highlights

Table 2-1. D4 Token Table (continued) Token 02A9 02AA 02AB 02AC 02AD 02AE 02B6 02B7 02B8 02C5 02C6 02C7 02C8 02C9 Setup Option Description DRAM Prefetcher Disables DRAM references from triggering DRAM prefetch requests. DRAM Prefetcher Turns on the DRAM prefetch unit in the Northbridge. HW Prefetch Training on SW Disables hardware prefetcher from considering software prefetches when detecting strides for prefetch requests. HW Prefetch Training on SW Enables Hardware prefetcher considers software prefetches when detecting strides for prefetch requests. (default) SR-IOV Global Enables BIOS support for SRIOV devices. Enable SR-IOV Global Disables BIOS support for SRIOV devices. Enable Memory Indicates all DIMMs in the system are operating at 1.5 Operating Voltage volts. Memory Indicates all DIMMs in the system are operating at Operating Voltage 1.35 volts. Memory This setting indicates the memory operating voltage Operating Voltage will be set automatically by the Memory initialization code and depending upon the installed DIMM's capability and the memory configuration of the system. This is the default setting and will set the Memory Operating voltage to the POR voltage. DCU Streamer Enables the DCU Streamer Prefetcher. (default) Prefetcher DCU Streamer Disables the DCU Streamer Prefetcher. Prefetcher Data Reuse Optimization Sets to enable for HPC applications. (default) Data Reuse Optimization Sets to disable for energy efficiency. QPI Bandwidth Sets to compute for computation-intensive Priority applications. (default) Using the System Setup Program 115

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192

Using the System Setup Program
115
02A9
DRAM Prefetcher
Disables DRAM references from triggering DRAM
prefetch requests.
02AA
DRAM Prefetcher
Turns on the DRAM prefetch unit in the Northbridge.
02AB
HW Prefetch
Training on SW
Disables hardware prefetcher from considering
software prefetches when detecting strides for
prefetch requests.
02AC
HW Prefetch
Training on SW
Enables Hardware prefetcher considers software
prefetches when detecting strides for prefetch
requests. (default)
02AD
SR-IOV Global
Enable
Enables BIOS support for SRIOV devices.
02AE
SR-IOV Global
Enable
Disables BIOS support for SRIOV devices.
02B6
Memory
Operating Voltage
Indicates all DIMMs in the system are operating at 1.5
volts.
02B7
Memory
Operating Voltage
Indicates all DIMMs in the system are operating at
1.35 volts.
02B8
Memory
Operating Voltage
This setting indicates the memory operating voltage
will be set automatically by the Memory initialization
code and depending upon the installed DIMM's
capability and the memory configuration of the
system. This is the default setting and will set the
Memory Operating voltage to the POR voltage.
02C5
DCU Streamer
Prefetcher
Enables the DCU Streamer Prefetcher. (default)
02C6
DCU Streamer
Prefetcher
Disables the DCU Streamer Prefetcher.
02C7
Data Reuse
Optimization
Sets to enable for HPC applications. (default)
02C8
Data Reuse
Optimization
Sets to disable for energy efficiency.
02C9
QPI Bandwidth
Priority
Sets to compute for computation-intensive
applications. (default)
Table 2-1.
D4 Token Table
(continued)
Token
Setup Option
Description