Dell PowerEdge C8000 Dell PowerEdge C8220 Hardware Owner's Manual - Page 108

Sets BMC LAN to get LAN IP from DHCP mode.

Page 108 highlights

Table 2-1. D4 Token Table (continued) Token 4895 4896 4897 4898 48A0 48A1 48A2 48A3 48A4 48A5 48A6 48A7 48A8 48A9 48AA 48AB 48AC 48AD 48AE Setup Option Description 5th Boot Device Sets the hard-drive as the 5th boot device. 5th Boot Device Sets RAID as the 5th boot device. 5th Boot Device Sets a USB storage device as the 5th boot device. 5th Boot Device Sets the CD/DVD ROM as thes 5th boot device. ACPI SPMI Table Disables the ACPI SPMI Table for BMC ROM update. ACPI SPMI Table Enables the ACPI SPMI Table for IPMI driver installation. BMC LAN Port Sets BMC LAN Port to Dedicated-NIC. Configuration BMC LAN Port Sets BMC LAN Port to Shared-NIC. Configuration BMC NIC IP Source Sets BMC LAN to get LAN IP from Static mode. BMC NIC IP Source Sets BMC LAN to get LAN IP from DHCP mode. IPv6 Mode Disables IPv6 internet protocol support. IPv6 Mode Enables IPv6 internet protocol support. IPv6 AutoConfig Disables IPv6 auto configuration. IPv6 AutoConfig Enables IPv6 auto configuration. Serial Port Mode Sets the console redirection baud rate to 3,8400 bits per second. Flow Control Selects none as the flow control for console redirection. Flow Control Selects hardware as the flow control for console redirection. Flow Control Selects software as the flow control for console redirection. Terminal Type The BIOS console redirection, if enabled, operates in VTUTF8 emulation model. See also tokens BFh, C0h, and D7h. 108 Using the System Setup Program

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208

108
Using the System Setup Program
4895
5th Boot Device
Sets the hard-drive as the 5th boot device.
4896
5th Boot Device
Sets RAID as the 5th boot device.
4897
5th Boot Device
Sets a USB storage device as the 5th boot device.
4898
5th Boot Device
Sets the CD/DVD ROM as thes 5th boot device.
48A0
ACPI SPMI Table
Disables the ACPI SPMI Table for BMC ROM
update.
48A1
ACPI SPMI Table
Enables the ACPI SPMI Table for IPMI driver
installation.
48A2
BMC LAN Port
Configuration
Sets BMC LAN Port to Dedicated-NIC.
48A3
BMC LAN Port
Configuration
Sets BMC LAN Port to Shared-NIC.
48A4
BMC NIC IP
Source
Sets BMC LAN to get LAN IP from Static mode.
48A5
BMC NIC IP
Source
Sets BMC LAN to get LAN IP from DHCP mode.
48A6
IPv6 Mode
Disables IPv6 internet protocol support.
48A7
IPv6 Mode
Enables IPv6 internet protocol support.
48A8
IPv6 AutoConfig
Disables IPv6 auto configuration.
48A9
IPv6 AutoConfig
Enables IPv6 auto configuration.
48AA
Serial Port Mode
Sets the console redirection baud rate to 3,8400 bits
per second.
48AB
Flow Control
Selects none as the flow control for console
redirection.
48AC
Flow Control
Selects hardware as the flow control for console
redirection.
48AD
Flow Control
Selects software as the flow control for console
redirection.
48AE
Terminal Type
The BIOS console redirection, if enabled, operates in
VTUTF8 emulation model. See also tokens BFh, C0h,
and D7h.
Table 2-1.
D4 Token Table
(continued)
Token
Setup Option
Description