Dell PowerEdge External Media System 1434 Dell PowerEdge R720 and R720xd Owner - Page 157
>. Re-seat PSU
View all Dell PowerEdge External Media System 1434 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 157 highlights
Error Code PSU0006 PSU0016 PSU0031 PSU0032 PSU0033 Message Information Message LCD Message Details Action Power supply type mismatch. Power supply is incorrectly configured. Check PSU. Power supplies should be of the same input type and power rating. Install matched power supplies and review proper configuration in this manual. Message LCD Message Details Action Power supply is absent. PSU is absent. Check PSU. The power supply has been removed or has failed. 1. Remove and reinstall the power supply. 2. Check cables and subsystem components in the system for damage. 3. If the issue persists, see Getting Help. Message LCD Message Details Action Message Details Action Message LCD Message Details Action Cannot communicate with power supply . Cannot communicate with PSU . Re-seat PSU. The power supply may operate, however power supply monitoring is degraded. System performance may be degraded. Remove and reinstall the power supply. If the issue persists, see Getting Help. The temperature for power supply is in a warning range. System performance may be degraded. Check the system operating environment, including airflow and inlet temperature. Check system logs for temperature and thermal component failures. The temperature for power supply is outside of the allowable range. PSU temperature outside of range. Check PSU. System performance may be degraded. Check the system operating environment, including airflow and inlet temperature. Check system logs for temperature and thermal component failures. 157