Dell PowerEdge M1000e Fabric OS Command Reference Manual Supporting Fabric - Page 285
FCIP FPGA GMAC and central ASIC FC loopback, PATH_TEST_GE_PORT_DISABLE_ERR
View all Dell PowerEdge M1000e manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 285 highlights
fcipPathTest 2 5 Central ASIC FC loopback 7 SFP and central ASIC FC loopback 8 PHY and central ASIC FC loopback 9 FCIP FPGA GMAC and central ASIC FC loopback -nframes count Specifies the number of frames to send. The test progresses until the specified number of frames are transmitted on each port. The default value is 100 (Brocade 7500/FR4-18i and Brocade 7800/FX8-24). -length data_length Specifies the data length of the frames used in the test (Brocade 7500/FR4-18i only). The default is 1,024; the maximum is 2,112 FC frames and 8,196 data packets. -compress mode Specifies the compression device for which to select or to bypass data compression for the test (Brocade 7500/FR4-18i only). By default, data compression is used. This setting is applicable only to path mode 1 and 2. Examples To run the test on slot 2 with PHY loopback sending 10 frames: switch:admin> fcippathtest --slot 2 -path 2 -nframes 10 Running fcippathtest Test Complete: fcippathtest Pass 10 of 10 Duration 0 hr, 1 min & 50 sec (0:1:50:942). passed. Diagnostics See Also When it detects failures, the test may report one or more of the following error messages: PATH_TEST_ERR PATH_TEST_CHIP_INIT_ERR PATH_TEST_IMAGE_ERR PATH_TEST_TIMEOUT_ERR PATH_TEST_HEARTBEAT_ERR PATH_TEST_INVALID_RESULT PATH_TEST_GE_PORT_ENABLE_ERR PATH_TEST_GE_PORT_DISABLE_ERR fcipChipTest Fabric OS Command Reference 253 53-1001764-02