Dell PowerEdge M710HD Fabric OS Command Reference Manual Supporting Fabric - Page 797
portShow, To display additional performance parameters for a circuit
View all Dell PowerEdge M710HD manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 797 highlights
portShow 2 L2CoS: F: 7 H: 5 M: 3 L: 1 DSCP: F: 0 H: 0 M: 0 L: 0 Flags: 0x00000000 To display additional performance parameters for a circuit: switch:admin> portshow fcipcircuit 2/12 0--perf Circuit ID: 2/12.0 Circuit Num: 0 Admin Status: Enabled Oper Status: Up Remote IP: 192.169.10.2 Local IP: 192.169.10.1 Metric: 0 Min Comm Rt: 1000000 Max Comm Rt: 1000000 SACK: On Min Retrans Time: 100 Max Retransmits: 8 Keepalive Timeout: 10000 Path MTU Disc: 0 VLAN ID: (Not Configured) L2CoS: (VLAN Not Configured) DSCP: F: 0 H: 0 M: 0 L: 0 Flags: 0x00000000 Flow Ctrl State: Off Connected Count: 6 Circuit Duration: 1 day, 2 hours, 40 minutes, 30 seconds Performance Statistics: Overall Throughput 1300544 Output Bytes 7 Bps 30s Avg, 13 Bps Lifetime Avg 10741 Output Packets 0 pkt/s 30s Avg, 0 pkt/s Lifetime Avg 1697876 Input Bytes 10 Bps 30s Avg, 17 Bps Lifetime Avg 14456 Input Packets 0 pkt/s 30s Avg, 0 pkt/s Lifetime Avg TCP Stats: 387921563652 Output Bytes 1671508568 Output Packets 189019870456 Input Bytes 1472851458 Input Packets Retransmits: 0 Round Trip Time: 102 ms Out Of Order: 0 Slow Starts: 0 To display QoS prioritization for the default circuit: switch:admin> portshow fcipcircuit 2/12 0--perf --qos Circuit ID: 2/12.0 Circuit Num: 0 Admin Status: Enabled Oper Status: Up Remote IP: 192.169.10.2 Local IP: 192.169.10.1 Metric: 0 Min Comm Rt: 1000000 Fabric OS Command Reference 765 53-1001764-02