Dell PowerEdge R750 EMC Technical Specifications - Page 20
Table 26. Thermal restriction matrix with BPS + 256 GB LRDIMMNon-GPU continued
![]() |
View all Dell PowerEdge R750 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Table 26. Thermal restriction matrix with BPS + 256 GB LRDIMM(Non-GPU) (continued) Configuration 8 x 2.5inch NVMe 16 x 2.5inch SAS/ SATA 16 x 2.5inch NVMe 24 x 2.5-inch SAS/ SATA 16 x 2.5inch SAS + 8 x 2.5inch NVMe 24 x 2.5inch NVMe 12 x 3.5-inch SAS/ SATA Rear storage No Rear Drives No No Rear Rear Drives Drives No Rear Drive s 2 x Rear 2.5inch, no rear fan 4 x Rear 2.5inch with fan No Rear Drives No Rear Drives No 2 x Rear Rear Drives 2.5- inch, no rear fan 4 x Rear 2.5inch with fan 225 W 230 W 235 W 240 W 250 W 265 W 270 W Ambie nt tempe rature 30°C NOTE: For all CPU TDP (105 W- 270 W) request HPR GOLD fan, T-Type HSK and processor HSK blank for 2.5-inch configurations. Table 27. Thermal restriction with ≤128 GB DIMM (GPU) Configu ration (Front storage ) Fan type CPU TDP/ cTDP A100 (80G) A100 GPU (Ambient temperature) A40 (max 2) A30 A10 8 x 2.5inch NVMe HPR SLVR fan 270 W 35°C 35°C 35°C 35°C 35°C 16 x 2.5inch SAS HPR GOLD fan 270 W 35°C 35°C 35°C 35°C 35°C 16 x 2.5inch NVMe HPR GOLD fan 270 W 35°C 35°C 35°C 35°C 35°C 24 x 2.5inch SAS HPR GOLD fan 270 W 35°C 35°C 35°C 35°C 35°C 16 x 2.5inch SAS + 8 x 2.5inch NVMe HPR GOLD fan 270 W 35°C 35°C 35°C 35°C 35°C M10 (max T4 (max 2) 6) 35°C 30°C 35°C 30°C 35°C 30°C 35°C 30°C 35°C 30°C 20 Technical specifications
![](/manual_guide/products/dell-poweredge-r750-emc-technical-specifications-b29b51d/20.png)