Thermal air restrictions, ASHRAE A3 environment for liquid cooling configuration
View all Dell PowerEdge R750 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Thermal air restrictions ASHRAE A3 environment for air cooling configuration ● Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced. ● PCIe SSD is not supported. ● BPS, 128 GB or greater capacity DIMMs are not supported. ● GPU and FPGA are not supported. ● Processor TDP greater than 165 W are not supported. ● HPR SLVR fans are required. ● Front storage is not supported in 12x3.5-inch SAS configuration. ● Rear drives are not supported. ● Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported. ● OCP 3.0 card is supported with 85°C active optic cable. ● BOSS 1.5 card is supported. ASHRAE A4 environment for air cooling configuration ● Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced. ● PCIe SSD is not supported. ● BPS, 128 GB or greater capacity DIMMs are not supported. ● GPU and FPGA are not supported. ● Processor TDP greater than 120 W are not supported. ● HPR SLVR fans are required. ● Front storage is not supported in 12x3.5-inch SAS configuration. ● Rear drives are not supported. ● BOSS 1.5 is not supported. ● OCP 3.0 card is supported with 85°C active optic cable and cards tier ≤4. ● Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported. ASHRAE A3 environment for liquid cooling configuration ● Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced. ● PCIe SSD is not supported. ● BPS, 128 GB or greater capacity DIMMs are not supported. ● GPU and FPGA are not supported. ● Rear drives are not supported. ● Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported. ● OCP 3.0 card is supported with 85°C active optic cable. ● BOSS 1.5 card is supported. ASHRAE A4 environment for liquid cooling configuration ● Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced. ● PCIe SSD is not supported. ● BPS, 128 GB or greater capacity DIMMs are not supported. ● GPU and FPGA are not supported. ● Front storage is not supported in 12x3.5-inch SAS configuration. ● Rear drives are not supported. ● BOSS 1.5 is not supported. ● OCP 3.0 card is supported with 85°C active optic cable and cards tier ≤4. ● Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported. 24 Technical specifications