nbrStateShow, portDisable, ucastAllShow, LSDAllShow, <queue ID>, actTimersShow
View all Dell PowerVault 50F manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 143 highlights
Table A-1. Errors (continued) Module Error Severity Explanation NBFSM NGBRSTATE (2) An error occurred in the neighbor Finite State. UCAST ADDPATH (1) RELICPDB (2) SPFCOST(3) MQ QREAD (1) A static path configuration failed. The path selection task received an E_Port SCN, but the port was already ISL. An error occurred with computing the unicast path tree. A task was unable to receive a message. QWRITE (1) SYS NOMEM (1) SYSCALL (2) TIMERS ENQFAIL (1) A task was not able to post a message on a queue. The system's memory is exhausted. A system call into VxWorks failed. An error occurred while setting a timer. Action Check the neighbor's state with the nbrStateShow command. If the state is not NB_ST_FULL, force a state change with the portDisable command followed by portEnable. After a few seconds, if the state is not NB_ST_FULL, reboot both the local and remote switches. Check command parameters. Run the ucastAllShow command. Contact customer support. Run the LSDAllShow command. Contact customer support. Run the command show with the ID of the queue reported in the error. Contact customer support. See "MQ-QWRITE Error" found later in this chapter for more information. Reboot the switch. Contact customer support. Reboot the switch. Contact customer support. Reboot the switch. Run the commands actTimersShow and timerShow . Contact customer support. support.dell.com Error Messages A-5