English The DCB118 charger is equipped with an internal fan designed to cool the battery pack. The fan will turn on automatically when the battery pack needs to be cooled. Never operate the charger if the fan does not operate properly or if ventilation slots are blocked. Do not permit foreign objects to enter the interior of the charger. LITHIUM-ION BATTERY PACKS ONLY Li-Ion tools are designed with an Electronic Protection System that will protect the battery pack against overloading, overheating or deep discharge. The tool will automatically turn off if the Electronic Protection System engages. If this occurs, place the lithium-ion battery pack on the charger until it is fully charged. Wall Mounting DCB107, DCB112, DCB113, DCB115, DCB118 These chargers are designed to be wall mountable or to sit upright on a table or work surface. If wall mounting, locate the charger within reach of an electrical outlet, and away from a corner or other obstructions which may impede air flow. Use the back of the charger as a template for the location of the mounting screws on the wall. Mount the charger securely using drywall screws (purchased separately) at least 1" (25.4 mm) long, with a screw head diameter of 0.28-0.35" (7-9 mm), screwed into wood to an optimal depth leaving approximately 7/32" (5.5 mm) of the screw exposed. Align the slots on the back of the charger with the exposed screws and fully engage them in the slots. Charger Cleaning Instructions WARNING: Shock hazard. Disconnect the charger from the AC outlet before cleaning. Dirt and grease may be removed from the exterior of the charger using a cloth or soft non-metallic brush. Do not use water or any cleaning solutions. Important Charging Notes 1. Longest life and best performance can be obtained if the battery pack is charged when the air temperature is between 65 °F and 75 °F (18 ° - 24 °C). DO NOT charge the battery pack in an air temperature below +40 °F (+4.5 °C), or above +104 °F (+40 °C). This is important and will prevent serious damage to the battery pack. 2. The charger and battery pack may become warm to the touch while charging. This is a normal condition, and does not indicate a problem. To facilitate the cooling of the battery pack after use, avoid placing the charger or battery pack in a warm environment such as in a metal shed or an uninsulated trailer. 3. If the battery pack does not charge properly: a. C heck operation of receptacle by plugging in a lamp or other appliance; b. C heck to see if receptacle is connected to a light switch which turns power off when you turn out the lights; c. M ove the charger and battery pack to a location where the surrounding air temperature is approximately 65 °F - 75 °F (18 ° - 24 °C); d. If charging problems persist, take the tool, battery pack and charger to your local service center. 4. The battery pack should be recharged when it fails to produce sufficient power on jobs which were easily done previously. DO NOT CONTINUE to use under these conditions. Follow the charging procedure. You may also charge a partially used pack whenever you desire with no adverse effect on the battery pack. 5. Foreign materials of a conductive nature such as, but not limited to, grinding dust, metal chips, steel wool, aluminum foil, or any buildup of metallic particles should be kept away from charger cavities. Always unplug the charger from the power supply when 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

10
English
The DCB118 charger is equipped with an internal fan designed to cool
the battery pack. The fan will turn on automatically when the battery
pack needs to be cooled.
Never operate the charger if the fan does not operate properly or if
ventilation slots are blocked. Do not permit foreign objects to enter the
interior of the charger.
LITHIUM-ION BATTERY PACKS ONLY
Li-Ion tools are designed with an Electronic Protection System that
will protect the battery pack against overloading, overheating or deep
discharge.
The tool will automatically turn off if the Electronic Protection System
engages. If this occurs, place the lithium-ion battery pack on the
charger until it is fully charged.
Wall Mounting
DCB107, DCB112, DCB113, DCB115, DCB118
These chargers are designed to be wall mountable or to sit upright on a
table or work surface.  If wall mounting, locate the charger within reach
of an electrical outlet, and away from a corner or other obstructions
which may impede air flow. Use the back of the charger as a template
for the location of the mounting screws on the wall. Mount the charger
securely using drywall screws (purchased separately) at least 1"
(25.4  mm) long, with a screw head diameter of 0.28–0.35" (7–9 mm),
screwed into wood to an optimal depth leaving approximately 7/32"
(5.5 mm) of the screw exposed. Align the slots on the back of the
charger with the exposed screws and fully engage them in the slots.
Charger Cleaning Instructions
WARNING:
Shock hazard. Disconnect the charger from the AC
outlet before cleaning. Dirt and grease may be removed from the
exterior of the charger using a cloth or soft non-metallic brush. Do not
use water or any cleaning solutions.
Important Charging Notes
1. Longest life and best performance can be obtained if the battery
pack is charged when the air temperature is between 65 °F and
75  °F (18  ° – 24  °C). DO NOT charge the battery pack in an air
temperature below +40 °F (+4.5 °C), or above +104 °F (+40 °C).
This is important and will prevent serious damage to the battery
pack.
2. The charger and battery pack may become warm to the touch
while charging. This is a normal condition, and does not indicate
a problem. To facilitate the cooling of the battery pack after use,
avoid placing the charger or battery pack in a warm environment
such as in a metal shed or an uninsulated trailer.
3. If the battery pack does not charge properly:
a.
Check operation of receptacle by plugging in a lamp or other
appliance;
b.
Check to see if receptacle is connected to a light switch which
turns power off when you turn out the lights;
c.
Move the charger and battery pack to a location where the
surrounding air temperature is approximately 65  °F – 75  °F
(18 ° – 24 °C);
d.
If charging problems persist, take the tool, battery pack and
charger to your local service center.
4. The battery pack should be recharged when it fails to produce
sufficient power on jobs which were easily done previously. DO
NOT CONTINUE to use under these conditions. Follow the
charging procedure. You may also charge a partially used pack
whenever you desire with no adverse effect on the battery pack.
5. Foreign materials of a conductive nature such as, but not limited
to, grinding dust, metal chips, steel wool, aluminum foil, or any
buildup of metallic particles should be kept away from charger
cavities. Always unplug the charger from the power supply when