Electrolux EFDE210TIW Installation Instructions English Spanish French - Page 10
Important
View all Electrolux EFDE210TIW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
10 Installation Instructions Direct Drain Kit, continued 6 To route the drain tube to the left of the dryer, secure the tube with the "P" clamp from the kit to the back of the dryer with the cabinet screw shown below. 8 Install the hose hanger from the kit onto the end of the hose and insert in drain. 7 To route the drain tube to the right of the dryer, route the tube across the back of the dryer and snap it into the "C" clips shown as below. IMPORTANT Follow these guidelines for proper drain hose installation: 1 The distance from the bottom of the drain tube sag to the top of highest part of drain tube should be no more than 20" (50 cm). Drain tube may need to be shortened with scissors if sag is greater than allowed. 2 The drain height location should be no more than 40" (100 cm) above the bottom of the dryer feet. MAX 20" (50 cm) MAX 40" (100 cm)