Electrolux EFDE210TIW Installation Instructions English Spanish French - Page 4

Installation Requirements - dryer

Page 4 highlights

4 Installation Requirements Electrical requirements for electric dryer NOTE Because of potentially inconsistent voltage capabilities, the use of this dryer with power created by gas powered generators, solar powered generators, wind powered generators or any other generator other than the local utility company is not recommended. CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp. time delay fuses or circuit breakers. Use separately fused circuits for washer and dryer. DO NOT operate a washer and a dryer on the same circuit. POWER SUPPLY - 3-wire or 4-wire, 208-240 volt, single phase, 60 Hz, Alternating Current. IMPORTANT This dryer is internally grounded to neutral unless it was manufactured for sale in Canada. Only a 4-conductor cord shall be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral link is prohibited for: (1) new branch circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes do not permit grounding through the neutral. Manufactured or mobile home installation Installation MUST conform to current Manufactured Home Construction & Safety Standard, Title 24 CFR, Part 32-80 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSAZ240 MH. Clearance requirements MINIMUM INSTALLATION CLEARANCES - Inches (cm) SIDES REAR TOP FRONT Alcove 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a Under Counter 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a 0" (0cm) 0" (0cm) 0" (0cm) OUTLET RECEPTACLE - NEMA 10-30R or NEMA 14-30R receptacle to be located so the power supply cord is accessible when the dryer is in the installed position. GROUNDING CONNECTION - See "Grounding requirements" in Electrical Installation section. 4-WIRE POWER SUPPLY CORD KIT (not supplied) 4-wire receptacle (NEMA type 14-30R) The dryer MUST employ a 4-conductor power supply cord NEMA 14-30 type SRDT or ST (as required) rated at 240 volt AC minimum, 30 amp, with 4 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers. For 4-wire cord connection instructions see ELECTRICAL CONNECTIONS FOR A 4-WIRE SYSTEM. NOTE Dryers manufactured for sale in Canada have factoryinstalled, 4-wire power supply cord (NEMA 14-30R). Closet Installation If installing the dryer in a closet, the unit must only be operated with the door in the open position to allow correct air circulation. See Use and Care Guide for more information. 3-WIRE POWER SUPPLY CORD KIT (not supplied) 3-wire receptacle (NEMA type 10-30R) The dryer MUST employ a 3-conductor power supply cord NEMA 10-30 type SRDT rated at 240 volt AC minimum, 30 amp, with 3 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers. For 3-wire cord connection instructions see ELECTRICAL CONNECTIONS FOR A 3-WIRE SYSTEM.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

4
Installation Requirements
MINIMUM INSTALLATION CLEARANCES - Inches (cm)
SIDES
REAR
TOP
FRONT
Alcove
0” (0 cm)
0” (0 cm)*
0” (0 cm)
n/a
Under Counter
0” (0 cm)
0” (0 cm)*
0” (0 cm)
n/a
Clearance requirements
Closet Installation
NOTE
Because of potentially inconsistent voltage capabilities,
the use of this dryer with power created by gas powered
generators, solar powered generators, wind powered
generators or any other generator other than the local utility
company is not recommended.
NOTE
Dryers manufactured for sale in Canada have factory-
installed, 4-wire power supply cord (NEMA 14-30R).
Electrical requirements for electric dryer
3-WIRE POWER SUPPLY CORD KIT (not supplied)
OUTLET RECEPTACLE - NEMA 10-30R or NEMA 14-30R
receptacle to be located so the power supply cord is
accessible when the dryer is in the installed position.
GROUNDING CONNECTION - See “Grounding requirements”
in Electrical Installation section.
The dryer MUST employ a 3-conductor power supply cord
NEMA 10-30 type SRDT rated at 240 volt AC minimum, 30
amp, with 3 open end spade lug connectors with upturned
ends or closed loop connectors and marked for use with
clothes dryers. For 3-wire cord connection instructions see
ELECTRICAL CONNECTIONS FOR A 3-WIRE SYSTEM.
4-WIRE POWER SUPPLY CORD KIT (not supplied)
The dryer MUST employ a 4-conductor power supply cord
NEMA 14-30 type SRDT or ST (as required) rated at 240
volt AC minimum, 30 amp, with 4 open end spade lug
connectors with upturned ends or closed loop connectors
and marked for use with clothes dryers. For 4-wire cord
connection instructions see ELECTRICAL CONNECTIONS
FOR A 4-WIRE SYSTEM.
3-wire receptacle
(NEMA type 10-30R)
4-wire receptacle
(NEMA type 14-30R)
IMPORTANT
This dryer is internally grounded to neutral unless it was
manufactured for sale in Canada.
Only a 4-conductor cord shall be used when the appliance
is installed in a location where grounding through the neutral
conductor is prohibited. Grounding through the neutral link is
prohibited for: (1) new branch circuit installations, (2) mobile
homes, (3) recreational vehicles, and (4) areas where local
codes do not permit grounding through the neutral.
Manufactured or mobile home installation
Installation MUST conform to current Manufactured Home
Construction & Safety Standard, Title 24 CFR, Part 32-80
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280) or Standard CAN/CSAZ240
MH.
CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp.
time delay fuses or circuit breakers. Use separately fused
circuits for washer and dryer. DO NOT operate a washer and
a dryer on the same circuit.
POWER SUPPLY - 3-wire or 4-wire, 208-240 volt, single phase,
60 Hz, Alternating Current.
If installing the dryer in a closet, the unit must only be
operated with the door in the open position to allow correct air
circulation. See Use and Care Guide for more information.
0”
(0cm)
0”
(0cm)
0”
(0cm)