Handshaking by DTR signal or X-on/X-off. The DTR signal changes, Space 0 +3 V to +27 V
View all Epson LQ-850X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 267 highlights
Signal level Mark (1) -3 V to -27 V Space (0) +3 V to +27 V Handshaking Handshaking by DTR signal or X-on/X-off. The DTR signal changes to mark-meaning the printer is not ready to receive data-when the number of bytes free in the input buffer goes down to 256. The signal changes to space-meaning that the printer is now readywhen the number of bytes in the input buffer rises to 528. Error handling A * character is printed if a parity error is detected. All other errors are ignored. Connector 6-pin DIN connector In this table, the direction of signals is given relative to the printer. Pin number 1 2 Signal TXD DTR Signal direction out out 3 RXD in 4 Not used 5 SG - 6 CG - Direction Transmits data for X-on/X-off Indicates whether or not the printer is ready to receive data. "Mark" level indicates printer is not ready to receive data. Receives data Signal (logic) ground level Printer chassis ground 8-14 Technical Specifications